ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION AUGUST 2016

ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION AUGUST 2016

University

30 Qs

quiz-placeholder

Similar activities

End Of 9 Weeks Study Guide (Spring)

End Of 9 Weeks Study Guide (Spring)

11th Grade - University

25 Qs

Chapter 1 - 4001 FTE Tutorial 2

Chapter 1 - 4001 FTE Tutorial 2

University

29 Qs

II ECE_PCB Design Quiz

II ECE_PCB Design Quiz

University

25 Qs

BEEE QUIZ 2024 - 2025 BATCH

BEEE QUIZ 2024 - 2025 BATCH

University

25 Qs

SEMICONDUCTOR

SEMICONDUCTOR

University

29 Qs

ELECTRO REVIEWER (FILL IN THE BLANK)

ELECTRO REVIEWER (FILL IN THE BLANK)

University

26 Qs

 ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

University

27 Qs

 ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION AUGUST 2016

ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION AUGUST 2016

Assessment

Quiz

Engineering

University

Easy

Created by

John Anthony Torres

Used 6+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a full-duplex?

Radar

Telephone

Tolemetry

Local Area Network

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a circuit breaker, the time duration from the instant of the fault extinction of arc is known as

Operating time

total clearing time

Lag time

lead time

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

34.5 KV to 69 KV is classified as

Low voltage

Medium voltage

High voltage

Extra high vol

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For an RL circuit, the power factor cannot be less than ______ or greater than

0,1

1,0

0, -1

-1, 0

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

is the overall energy program formulated and updated yearly by the DOE, submitted to the congress pursuant to RA 7638.

Philippine Energization Program

Philippine Energy Plan

Philippine Electrification Program

Philippine Electrification Plan

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The lighting load for a dwelling expressed in terms of a unit load in volt ampere per square meter must be at least

24

12

16

2

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The capacitors of power factor correction are rated in terms of

KV

KW

KVA

KVAR