
Condensing Boilers Worksheet
Authored by James Ramsden
Construction
Professional Development
Used 1+ times

AI Actions
Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...
Content View
Student View
19 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the maximum return temperature at which modern condensing boilers will work in condensing mode?
60 degrees
50 degrees
70 degrees
82 degrees
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Why is it necessary to slow the flow of water through each radiator in a modern condensing boiler system?
To increase the pressure in the system
To allow time for the water to cool
To reduce noise from the radiators
To prevent leaks in the pipes
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
According to the text, what is the typical maximum temperature setting for central heating in most boilers?
50 degrees
65 degrees
82 degrees
21 degrees
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Explain why most boilers are installed with their heating and hot water settings at maximum, and discuss one potential drawback of this practice for boiler efficiency.
To ensure the system heats rooms quickly; drawback: increased noise
To meet system design for cold weather and avoid callbacks; drawback: not good for boiler efficiency
To reduce installation time; drawback: higher installation cost
To prevent water leaks; drawback: lower water pressure
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
At what temperature is it generally sufficient to set your boiler for most of the year, according to the text?
82 degrees
65 degrees
50 degrees
14 degrees
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Why does the majority of fuel used in heating come from the initial start up of the radiators?
Because the radiators are already warm
Because the radiators must heat up from room temperature to the desired temperature
Because the boiler is set to maximum capacity
Because the thermostat is always on
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
According to the text, when does the thermostat stop the boiler?
When the room temperature drops below 14 degrees
When the heating is satisfied
When the boiler is set to 65 degrees
When the radiators are cold
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?
Similar Resources on Wayground
Popular Resources on Wayground
15 questions
Fractions on a Number Line
Quiz
•
3rd Grade
20 questions
Equivalent Fractions
Quiz
•
3rd Grade
25 questions
Multiplication Facts
Quiz
•
5th Grade
54 questions
Analyzing Line Graphs & Tables
Quiz
•
4th Grade
22 questions
fractions
Quiz
•
3rd Grade
20 questions
Main Idea and Details
Quiz
•
5th Grade
20 questions
Context Clues
Quiz
•
6th Grade
15 questions
Equivalent Fractions
Quiz
•
4th Grade
Discover more resources for Construction
20 questions
Black History Month Trivia Game #1
Quiz
•
Professional Development
100 questions
Screening Test Customer Service
Quiz
•
Professional Development
20 questions
90s Cartoons
Quiz
•
Professional Development
10 questions
Reading a ruler in Inches
Quiz
•
4th Grade - Professio...
16 questions
Parallel, Perpendicular, and Intersecting Lines
Quiz
•
KG - Professional Dev...
12 questions
Valentines Day Trivia
Quiz
•
Professional Development