Boiler and Cooling Water Quiz

Boiler and Cooling Water Quiz

Professional Development

9 Qs

quiz-placeholder

Similar activities

PPE -Steam Power Plant 2 SMK GIET

PPE -Steam Power Plant 2 SMK GIET

University - Professional Development

10 Qs

Quality Meeting April 2025

Quality Meeting April 2025

Professional Development

10 Qs

Quality Meeting Feb'2025

Quality Meeting Feb'2025

Professional Development

10 Qs

Training question

Training question

6th Grade - Professional Development

10 Qs

Instrument Air system

Instrument Air system

Professional Development

14 Qs

Sales

Sales

Professional Development

7 Qs

3938830021082

3938830021082

Professional Development

10 Qs

Quality Meeting Bulan Mei 2025

Quality Meeting Bulan Mei 2025

Professional Development

10 Qs

Boiler and Cooling Water Quiz

Boiler and Cooling Water Quiz

Assessment

Quiz

Education

Professional Development

Hard

Created by

Sir Khen

FREE Resource

9 questions

Show all answers

1.

OPEN ENDED QUESTION

30 sec • 1 pt

What are the key parameters and indicators of water quality for boiler and cooling systems that are essential for effective operation and maintenance onboard? Give atleast 6

Evaluate responses using AI:

OFF

2.

OPEN ENDED QUESTION

30 sec • 1 pt

What is the importance of maintaining correct parameters in boiler and cooling water?

Evaluate responses using AI:

OFF

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the pH value range that should be maintained in boiler water to prevent acidic corrosion?

10.5 to 11.0

5.0 to 9.4

7.0 to 8.5

0 to 14

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum concentration of sulfite required in boiler water for the removal of dissolved oxygen?

10 PPM

20 PPM

30 PPM

50 PPM

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum total hardness that should not be exceeded in boiler water?

50 PPM

100 PPM

200 PPM

700 PPM

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the desirable concentration of phosphates in boiler water for complete reaction with calcium hardness?

10 – 20 PPM

20 – 30 PPM

30 – 50 PPM

50 – 70 PPM

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the effect of high boiler alkalinity, which is in excess of 700 PPM?

Corrosion

Embrittlement of steel

Scaling

Foaming

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary corrosive agent of steam-generating systems?

Dissolved oxygen

Oil content

Hardness

Alkalinity

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the significance of chloride ion content in boiler feed water?

It helps in scaling

It can cause foaming

It prevents corrosion

It increases pH