Inspection and Testing Quiz

Inspection and Testing Quiz

Vocational training

20 Qs

quiz-placeholder

Similar activities

Earth Faults and Protection Quiz

Earth Faults and Protection Quiz

12th Grade - University

20 Qs

Basic Electronics

Basic Electronics

5th - 9th Grade

17 Qs

Inspection and Testing - 15Q Mock Quiz

Inspection and Testing - 15Q Mock Quiz

KG - University

15 Qs

Insulation Resistance Test Quiz

Insulation Resistance Test Quiz

12th Grade

16 Qs

Multimeters

Multimeters

Professional Development

20 Qs

safety in the workshop and factors of electricity

safety in the workshop and factors of electricity

7th - 10th Grade

20 Qs

Cannock EIC Quiz

Cannock EIC Quiz

Professional Development

17 Qs

Inspection and Testing Quiz

Inspection and Testing Quiz

Assessment

Quiz

Other

Vocational training

Hard

Created by

Antony Frear

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which document must be completed and issued after the initial verification of a new electrical installation?

Minor Electrical Installation Works Certificate

Electrical Installation Certificate

Periodic Inspection Report

Building Regulations Certificate

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of insulation resistance testing in an electrical installation?

To check the continuity of conductors

To ensure there are no short circuits or earth faults

To measure the voltage drop

To test the operation of RCDs

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which instrument is typically used to measure earth loop impedance?

Insulation resistance tester

Continuity tester

Earth loop impedance tester

Clamp meter

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum insulation resistance value required for a new domestic installation at 500V DC, according to BS 7671?

0.5 MΩ

1.0 MΩ

2.0 MΩ

5.0 MΩ

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which regulation covers the requirements for initial verification of an electrical installation?

BS 7671 Regulation 411

BS 7671 Regulation 612

BS 7671 Regulation 522

BS 7671 Regulation 701

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct sequence for dead testing during initial verification?

Continuity, insulation resistance, polarity

Polarity, insulation resistance, continuity

Insulation resistance, continuity, polarity

Continuity, polarity, insulation resistance

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a live test?

Earth loop impedance

RCD testing

Continuity of protective conductors

Prospective short-circuit current