1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A combination gas valve is a gas valve that has been combined with which of these?
Pilot valves
Gas regulators
Pressure regulators
Natural valves
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What type of gas valve is an NC valve with a plunger used to open the valve?
Solenoid valve
Heat motor valve
Diaphragm valve
Straight plate valve
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What type of gas valve has an electric heating element or resistance wire wound around a rod attached to a valve?
Heat motor-controlled valve
Solenoid valve
Diaphragm valve
Straight plate valve
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following is a feature of heat exchangers?
Many burners are located at the bottom
They have slow and inconsistent transfer of heat
They are made of durable plastics
Sections each have six or seven burners running simultaneously
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A technician repairing a gas furnace noticed that the heat exchanger has an acidic condensation running down the flue pipe that is deteriorating the flue system. What is likely causing this problem?
There is too much airflow across the heat exchanger
There is not enough airflow across the heat exchanger
The flue gasses are too hot
The heat exchanger has overheated
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What kinds of tubes does a heat exchanger typically have?
Both L-shaped and S-shaped tubes
Both T-shaped and O-shaped tubes
Only L-shaped tubes
Only O-shaped tubes
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A technician servicing gas furnaces notices that when the gas furnace kicks on, it blows cold air. The technician thinks this is happening because air is blowing out into the duct system before the heat exchanger can produce warm air. What is likely causing this cold air problem?
The fan switch is turning on the blower before the air is hot
The limit switch will not allow the heat exchanger to warm up
The heat exchanger is broken
The pilot is igniting too quickly
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?