Wall System M.6

Wall System M.6

9th - 12th Grade

8 Qs

quiz-placeholder

Similar activities

Ausan, BTVTED CT

Ausan, BTVTED CT

3rd Grade - University

10 Qs

Document Analysis Quiz

Document Analysis Quiz

9th Grade

12 Qs

SSC Topic C280

SSC Topic C280

9th Grade

7 Qs

QUIZZ PENULANGAN

QUIZZ PENULANGAN

11th Grade

11 Qs

Planer Safety Test - Test #2

Planer Safety Test - Test #2

9th Grade - University

13 Qs

Jointer Safety Test - Test #3

Jointer Safety Test - Test #3

9th - 12th Grade

13 Qs

L1 Cavity - Air Bricks and Ties

L1 Cavity - Air Bricks and Ties

12th Grade

11 Qs

MATERI  SYSTEM KOORDINAT 2D

MATERI SYSTEM KOORDINAT 2D

11th Grade

12 Qs

Wall System M.6

Wall System M.6

Assessment

Quiz

Construction

9th - 12th Grade

Hard

Created by

Bernardo Olguin

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

8 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Stud spacing of 16" on center or 24" on center are used when framing walls because?

they are multiples of 8"

they divide evenly into 48"

to save money when purchasing materials

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A wall erected on a concrete slab with a 8'-1" ceiling height using 2 × 6 stock with 5/8" gypsum board ceiling requires studs with a length of?

91"

92-1/8"

93-1/8"

94"

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

when framed partition butts against masonry wall, 1 x 2 furring strip is applied at point of intersection to _?

fix

to provide a nailing surface for the gypsum board

the

answers

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Carpenters build concrete ____ in commercial construction where the framework is made of steel and concrete ?

fix

the

forms

answers

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When laying out a wall, why should the sole plate and the top plate be different lengths?

To provide a nailing surface for ceiling joists

To use up shorter lengths of lumber

To eliminate the need for splicing


To prevent butt joints from falling directly above each other

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Width of a window header or door opening is usually width of ?

fix

rough opening plus width of trimmer studs

the

answers

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements about steel studs is not true?

Steel studs are stronger and lighter than wood studs

Steel studs will not warp, swell, split, or burn.

Steel studs are harder to handle than wood studs.

Steel studs are connected using self-tapping sheet-metal screws.

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What length of common stud is needed when the building has a 1/2" gypsum-board ceiling, a 5/8" underlayment, a 3/4" subfloor, and an 8' ceiling height?

92-2/8"

93-3/8"

91-1/4"