2024 Practice Test #6

2024 Practice Test #6

Professional Development

100 Qs

quiz-placeholder

Similar activities

CBT-Unit W03- User Interface Design

CBT-Unit W03- User Interface Design

Professional Development

103 Qs

Big Test Dude Part 3

Big Test Dude Part 3

Professional Development

99 Qs

DNI Calon RGM

DNI Calon RGM

Professional Development

100 Qs

FINNISH VERB TYPES AND SPELLING MKGB79F

FINNISH VERB TYPES AND SPELLING MKGB79F

Professional Development

100 Qs

PAEMANWASOS

PAEMANWASOS

Professional Development

100 Qs

KOMPETENSI TEKNIS PJOK_7

KOMPETENSI TEKNIS PJOK_7

Professional Development

100 Qs

Module 6 QC Green 100-200

Module 6 QC Green 100-200

Professional Development

100 Qs

NURSING PRACTICE 1 📌 FINAL PROOF READ MAY NLE 2022

NURSING PRACTICE 1 📌 FINAL PROOF READ MAY NLE 2022

Professional Development

100 Qs

2024 Practice Test #6

2024 Practice Test #6

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Mike Sommerfeldt

Used 3+ times

FREE Resource

100 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Fittings with internal seals shall be limited to only those parts _____________.

essential for sealing or creating a dielectric break

where medical-surgical vacuum or WAGD are used

that are part of a dental vacuum system

none that are listed are approved

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a non-anesthetizing area, on which side of a zone valve shall the area alarm

pressure/vacuum sensor be located?

station outlet/inlet

upstream side

source

NFPA 99 does not specify a requirement

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a category 2 dental system oxygen piping shall be ___________.

1 size larger than nitrous oxide

1 size smaller than nitrous oxide

the same size as nitrous oxide

there are no requirements for oxygen and nitrous oxide in a category 2 system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The instrument air dew point high alarm from each compressor site will indicate at the master alarm panels when the line pressure dew point is greater than ___.

-22º F

-32º F

-39º F

-44º F

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to NFPA 99 the minimum distance between a bulk cryogenic source and combustible materials shall be ______ feet.

25

50

75

100

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Final line pressure controls shall be sized to ___ of the peak calculated demand.

50%

100%

110%

not specified

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Medical air compressor intake shall be located outdoors a minimum distance of ____ feet above the ground.

10

15

20

25

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?

Discover more resources for Professional Development