Ethylene Purification and Refrigeration Systems

Ethylene Purification and Refrigeration Systems

Assessment

Interactive Video

Physics, Chemistry, Science

10th Grade - University

Hard

Created by

Sophia Harris

FREE Resource

The video tutorial explains the process of expanding a vapor compression refrigerator into a two-stage system using ethylene as a refrigerant. It covers the construction, testing, and optimization of the system, addressing challenges such as impurities in ethylene and inefficiencies in heat transfer. The video concludes with plans for further improvements and achieving lower temperatures.

Read more

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary goal of expanding the vapor compression refrigerator into a two-stage system?

To increase the efficiency of the refrigerator

To reach a temperature of -100°C

To use less energy

To reduce the size of the refrigerator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a multi-stage refrigerator, what does the cold end of the first stage do?

Increases the pressure

Condenses the refrigerant

Cools the warm end of the second stage

Heats the warm end of the second stage

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is an oil separator necessary in the second stage of the refrigerator?

To increase the flow rate

To increase the pressure

To prevent the compressor oil from freezing and clogging the system

To reduce the temperature

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the after cooler in the second stage?

To make the process more efficient by removing heat from compression

To condense the refrigerant

To reduce the pressure

To increase the temperature

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the function of the buffer tank in the second stage?

To increase the temperature

To ensure high side pressure can be as high as possible

To condense the refrigerant

To reduce the flow rate

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What issue did the narrator face with the ethylene during testing?

It was too pure

It was too expensive

It was contaminated with hydrogen

It was too cold

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why did the narrator replace the plate heat exchanger with a coaxial coil?

To increase the pressure

To improve heat transfer efficiency

To reduce the temperature

To increase the flow rate