Insulation Resistance Testing Procedures

Insulation Resistance Testing Procedures

Assessment

Interactive Video

Science, Professional Development, Life Skills

10th Grade - University

Hard

Created by

Emma Peterson

FREE Resource

The video tutorial covers the insulation resistance test, the third dead test according to BS 7671. It begins with an overview and preparation steps, ensuring all circuits are in the correct position and sensitive devices are removed. The tutorial then details the procedure for conducting the test, including testing between live conductors and to earth, and recording results. It concludes with finalizing the test, ensuring all steps are followed, and documenting the results.

Read more

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of the insulation resistance test?

To verify the operation of RCCBs

To ensure the installation is live

To measure the resistance between conductors and earth

To check the continuity of protective conductors

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why is it important to leave all circuits in the 'on' position during the continuity test?

To ensure RCCBs are operational

To avoid unnecessary power consumption

To prevent damage to electronic devices

To ensure the insulation resistance test reaches the front of the plate

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be done with electronic devices like RCCBs during the insulation resistance test?

Leave them in the on position

Increase their voltage

Remove them from the circuit

Leave them in the off position

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to BS 7671, how should the insulation resistance test be conducted?

Between neutral and earth only

Between line and neutral only

Between live conductors and earth

Between line and earth only

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the significance of recording the worst reading during the insulation resistance test?

To avoid retesting

To ensure the highest safety standards

To simplify the testing process

To comply with BS 7671 requirements

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of using a link during the insulation resistance test setup?

To increase the voltage

To connect the RCCBs

To ensure a short circuit is present

To test the continuity of the circuit

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the role of the mega MFT in the insulation resistance test?

To measure current

To provide a test voltage of 500 volts DC

To connect the RCCBs

To isolate the circuit

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?