Chiller COP - Coefficient Of Performance

Chiller COP - Coefficient Of Performance

Assessment

Interactive Video

Architecture, Physics, Science

University

Hard

Created by

Quizizz Content

FREE Resource

The video tutorial explains the importance of measuring chiller efficiency using the Coefficient of Performance (COP). It details how to calculate COP by measuring electricity input and cooling output, using both metric and imperial units. The tutorial also discusses factors affecting chiller efficiency, such as compressor speed and load conditions, and provides practical examples to illustrate these concepts.

Read more

7 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does a high coefficient of performance (COP) indicate about a chiller's efficiency?

The chiller is operating at a constant load.

The chiller is not functioning properly.

The chiller is using more electricity than it produces in cooling.

The chiller is producing more cooling energy than the electricity it consumes.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is NOT a method to obtain the electricity input for calculating COP?

Connecting a temporary energy meter

Estimating based on past bills

Checking the building management system

Using a digital energy meter

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the example calculation, what is the COP when the chiller provides 2500 kilowatts of cooling using 460 kilowatts of electricity?

3.5

7.2

1.0

5.4

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why might a chiller not operate at optimal performance even with a high COP?

The COP is not a reliable measure of efficiency.

The chiller might be using outdated technology.

There could be room for improvement in operational conditions.

The chiller is too new.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the impact of a variable speed compressor on chiller efficiency?

It always operates at full load.

It offers optimal efficiency during part load conditions.

It is less efficient at part load conditions.

It does not affect the efficiency.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a significant factor that affects the COP of a chiller throughout the year?

The type of refrigerant used

The color of the chiller

The speed of the compressor

The brand of the chiller

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How does the load condition of a building typically affect the choice of compressor speed?

Full load conditions favor variable speed compressors.

Part load conditions favor constant speed compressors.

Part load conditions favor variable speed compressors.

Load conditions do not affect compressor speed choice.