The video tutorial explains the Wye-Delta connection, starting with the primary side where H2 bushings are connected but not grounded. The secondary side uses one X2 bushing as neutral, with specific connections for X1 and X3. The power leg is identified as one and a half coils from the neutral, crucial for avoiding excessive voltage in single-phase loads. The Wye-Delta system offers flexibility for three or four-wire systems and can temporarily operate with two transformers, though at reduced efficiency.

Read more

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the first step in setting up a Wye-Delta connection on the primary side?

Connect H2 bushings to ground

Connect H1 bushings to each phase

Connect all H2 bushings together

Connect all H1 bushings to ground

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does the phrase 'Wye-Delta you float' imply?

H1 bushings are connected to ground

H1 bushings are floating

H2 bushings are grounded

H2 bushings are connected together but not grounded

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which bushing is used as the neutral in the secondary side connection?

X1 bushing

H2 bushing

X3 bushing

X2 bushing

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How are the X1 and X3 bushings connected in the secondary side setup?

X1 to X2 on the same transformer

X1 to X3 on the adjacent transformer

X1 to X3 on the far right transformer

X1 to X3 on the same transformer

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the significance of the power leg in a Wye-Delta connection?

It is used for single-phase loads

It is directly connected to ground

It is used for grounding the system

It is one and a half coils from the neutral

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why should the power leg not be used for single-phase loads?

It is not connected to the neutral

It provides insufficient voltage

It can cause overvoltage and damage electronics

It is only used for grounding

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is one advantage of a Wye-Delta system?

It can only be used in a three-wire system

It allows for temporary operation with two transformers

It requires all transformers to be grounded

It is more efficient than other systems

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?