EPA type 3 video quiz

EPA type 3 video quiz

Assessment

Interactive Video

Instructional Technology

2nd Grade

Practice Problem

Easy

Created by

Jansen Godley

Used 1+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are the three main types of EPA 608 certifications, in addition to the Core certification?

Small appliances, medium-pressure appliances, very high-pressure appliances

Small appliances, high-pressure appliances, very low-pressure appliances

Residential appliances, commercial appliances, industrial appliances

Type A, Type B, Type C

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What unique characteristic distinguishes a leak on the low-pressure side of a low-pressure appliance from a leak on the high-pressure side?

Refrigerant will leak out at a faster rate.

Air will be sucked into the system.

The system will immediately shut down.

The leak will be undetectable.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary function of a purge unit in a low-pressure refrigeration system?

To increase the system's cooling capacity.

To recover refrigerant from the system.

To remove non-condensable gases (like air) from the system.

To add refrigerant to the system.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the required evacuation level for a low-pressure appliance using recovery equipment manufactured after November 15, 1993?

0 inches of Hg vacuum

4 inches of Hg vacuum

25 mm Hg absolute

10 inches of Hg vacuum

5.

MULTIPLE CHOICE QUESTION

30 sec • Ungraded

Are you enjoying the video lesson?

Yes

No

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum test pressure recommended when pressure testing a low-pressure device to avoid blowing the rupture disk?

5 PSI

10 PSI

20 PSI

50 PSI

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When charging a low-pressure refrigerant into a chiller unit where water is present, what is the initial step to prevent freezing and damage?

Add liquid refrigerant slowly

Charge with vapor until pressure is above 32° saturation

Evacuate the system completely

Use a heating blanket on the chiller barrel

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?