Electrical Fault Diagnosis and Rectification

Total questions: 10

Worksheet time: 8mins

Name
Class
Date
1.

what is the first step of safe isolation

a)

Identify the circuit

b)

Isolate the circuit

c)

Seek permission to Isolate

d)

Lock of the supply

2.

A customer reports their main RCD is constantly tripping. The most likely fault would be;

a)

A Faulty appliance

b)

Rodent damage to cables

c)

To many appliances plugged in

d)

Human error during installation

3.

the correct instrument to check a circuit is dead is:

a)

earth fault loop impedance tester

b)

low resistance ohms meter

c)

approved voltage indicator

d)

insulation resistance tester

4.

To check the resistance of cable insulation you would use:

a)

An approved voltage indicator

b)

Multi-meter

c)

Insulation resistance tester

d)

Low resistance ohmmeter

5.

A customer has nailed through a cable whilst pitting up a picture. the correct rectification would be.

a)

Renew the leg of cable completely and test the circuit

b)

Joint the cable where the nail has penetrated the cable, and test

c)

Remove the nail and hope for the best

d)

Leave the nail in the cable and plaster over it.

6.

An existing 4 year old 3 phase motor has started to run slowly when on load, its extremely loud and the bearings are satisfactory. The possible fault could be

a)

One of the phase winding's have become open circuit

b)

Their is a short circuit between 2 phase windings

c)

The supply to the motor has been isolated

d)

The bearings are too tight

7.

A MICC cable has been installed underground to feed a fish pond in a garden center. The cable has failed and is causing the fuse to blow. The possible fault could be

a)

too much load on the pond

b)

the outer sheath has became damaged and penetrated the inner cores

c)

too much voltage drop at the pond

d)

the cable has reached its lifespan and decided to give up

8.

A fluorescent light fitting has failed to strike and is flickering, the possible faults could be:

a)

the supply voltage has dropped a little

b)

the starter could be faulty

c)

a short circuit fault is present on the supply circuit

d)

the tube could be faulty

9.

An immersion heater is causing water to over heat, the possible fault causing this could be:

a)

the heater is drawing too much current

b)

the thermostat is stuck in the on position

c)

the heater is drawing too much voltage

d)

the thermostat is stuck in the off position

10.

A 13 amps socket supplying a 3kw heater has burnt contacts; which is the correct statement below

a)

the socket should be taped up and changed at the next convenient opportunity.

b)

sockets shouldn't be used to supply 3kw heaters, this should be changed immediately to a 20amp double pole switch

c)

the socket isnt badly damaged therefore should be left alone until a major fault occurs.

d)

change the socket immediately.