wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Sanitaryware level 2 part 2

Total questions: 23

Worksheet time: 12mins

Name
Class
Date
1.

A new automatic water flow cut off device has been correctly installed to an automatic flushing cistern but is not performing to specification. The appropriate action the plumber should take is to

a)

advise the customer to return the item

b)

strip the item down and attempt to repair it

c)

get the item replaced under warranty

d)

get the manufacturer to visit site and replace it.

2.

The main purpose of a dual flush WC cistern is to

a)

increase the volume of water to flush the pan

b)

allow the cistern to be connected to a siphonic pan

c)

prevent the possibility of the cistern overflowing.

d)

significantly improve water conservation

3.

A partially blocked outlet from a WC would cause

a)

the siphon to malfunction

b)

the WC cistern to overflow

c)

the bath waste pipe to be blocked

d)

failure of the pan to clear its contents completely.

4.

A pop-up waste fitted to a wash basin fails to retain the water when in the closed position. To rectify the problem a plumber should first

a)

adjust the plug lift at the control port seal connection

b)

Increase the plug lift by rotating the adjuster anti-clock wise

c)

reduce the plug lift by rotating the adjuster clock wise

d)

adjust the shackle so that it is closer to the waste fitting.

5.

Which of the following jointing materials is suitable for making a plastic basin waste into a vitreous china wash basin?

a)

Linseed oil putty

b)

Jointing compound

c)

Silicone sealant

d)

Hemp.

6.

What is the recommended flushing volumes of a dual flush wc cistern

a)

6 and 5 litres

b)

6 and 4 litres

c)

8 and 4 litres

d)

9 and 4.5 litres

7.

The cold water supply to a macerator WC should be isolated by a

a)

Service valve

b)

Gate valve

c)

Supply stop valve

d)

Single check valve

8.

Whilst re-washering a tap the plumber notices that the washbasin is cracked. The plumber’s next action would be to

a)

tell the customer and then agree the next action

b)

get the appropriate tools and renew the wash basin

c)

contact the manufacturer and arrange a replacement

d)

contact the supplier and arrange a replacement.

9.

The electrical supply to a sink waste disposal unit should be wired from

a)

a fused double pole switch

b)

the meter connection

c)

a pull switch in the kitchen

d)

an un-switched outlet.

10.

Which of the following would cause the least disruption to the customer when all the WC fitments in a busy public toilet are being replaced?

a)

Close the toilets down and provide external portable WC facilities

b)

Carry out the work in stages outside normal working hours

c)

Organise additional plumbers to get the job done much quicker

d)

Keep the toilets open and supply internal portable WC facilities.

11.

Guidance on workmanship related to sanitation systems is provided by which British Standard?

a)

BS 1876

b)

BS 6700.

c)

BS 8000

d)

BS 12056.

12.

On a routine maintenance inspection, which one of the following checks would be necessary to ensure that the system complies with regulations?

a)

That WC pans on solid floors are not bedded on a sand and cement mix.

b)

Vent pipes are terminated with a wind cowl to avoid loss of trap seal

c)

Sanitation pipework is always one size smaller than the trap outlet

d)

Rodding points to discharge pipework are checked for ease of access.

13.

If a newly fixed sanitary appliance does not perform to specification, the plumber should

a)

advise the customer to return the item

b)

get the item replaced under warranty

c)

strip the item down and attempt to repair it

d)

get the manufacturer to visit site and replace it.

14.

The maximum flush capacity of a new WC suite is

a)

6.0 litres

b)

6.5 litres

c)

8.0 litres

d)

9.0 litres

15.

The purpose of a sparge pipe is to

a)

create a vacuum between a WC cistern and siphonic pan

b)

join the overflow outlet to the waste fitting on a bath

c)

evenly distribute water over the face of a slab urinal

d)

limit the flow of water to an automatic flushing cistern.

16.

An acceptable jointing material that can be used to make a watertight seal between an unslotted waste and a plastic shower tray is

a)

linseed oil putty

b)

silicone sealant

c)

jointing compound

d)

hemp.

17.

Before installing a waste disposal unit, a plumber should check that the

a)

water pressure to the unit is adequate for it to function correctly

b)

unit has a cut out device that will turn it off should it jam

c)

pipework from the unit cannot discharge directly into a soil stack

d)

waste disposal outlet fitting is a minimum diameter of 19 mm.

18.

Which of the following should be the first action when replacing a pump on a jacuzzi?

a)

Carry out a safe electrical isolation procedure of the pump.

b)

Apply cross bonding between the pump and the metal bath frame

c)

Turn off the hot and cold water supply and drain the pipework

d)

Remove the anti vibration mounts from the pump casing.

19.

Where should the electrical supply switch to a WC macerator NOT be sited

a)

In the bathroom or showeroom

b)

In the Cloakroom

c)

In the concealed ducting

d)

Outside the room the unit is sited

20.

What needs to be considered before installing a WC waste macerator in a property

a)

The mains cold pressure is high enough

b)

That there is another WC in the building connected to the main drainage

c)

The flush volume of the WC cistern

d)

That there is a sufficient 40A electrical supply

21.

What should be the correct gradient for a waste pipe entering the macerator unit

a)

1;40

b)

1;20

c)

1;10

d)

1;60

22.

What is the purpose of the non-return valve within the macerator unit?

a)

The non-return valve prevents waste water heating up from the heat of the motor

b)

To make the motor run smoothly

c)

To make the discharge quieter

d)

The non-return valve prevents waste under gravity pressure from re-entering the unit

23.

What should be avoided on the outlet pipework from a WC macerator

a)

90 degree bends

b)

Vertical lift

c)

Horizontal pipework

d)

45 degree bends