Font size
WorksheetsNPA 1130 - Unit 10
Total questions: 50
Worksheet time: 50mins
The grounding conductor installed in electrical control panel should comply with ___________ standards.
Saudi Building Code 401
Saudi Building Code 801
Saudi Building Code 501
Saudi Building Code 601
Ground ____________ terminal blocks are used to connect ground wires between panels.
terminal blocks
ground fault
phase
ground shield
SBC 401 requires that wire used for grounding conductors must be either solid or ____________.
stranded
straped
taped
winding
During normal condition the ground wire will not carry current.
TRUE
FALSE
One way to verify the proper installation of the grounded system is to check the _____________ with a DMM.
resistance
voltage
current
capacitor
What should be the value of ground or earth resistance?
zero ohms
infinity
1 ohm
20 ohms
____________ are used in electrical panels to route wire between panel components
wireways
cable
panel
screw
A wire ____________ must be determined before it can be installed in an electrical panel.
length
volume
area
thickness
A wire length must be determined before it can be installed in an electrical panel.
TRUE
FALSE
Checking wire length is not needed before installation.
TRUE
FALSE
It is important to properly strip and ___________ a wire before it is terminated inside electrical panel.
label
winding
lift
cut
A ____________ tool is used to pull wires when the conduit is long or has many bends.
fish tape
electrical tape
insulation tape
masking tape
A fish tape tool is used to pull wires when the conduit is long or has many bends.
TRUE
FALSE
A fish tape tool is NOT used to pull wires when the conduit is long or has many bends.
TRUE
FALSE
Compare to other wire bundling methods, wireways require MORE space inside the panel.
TRUE
FALSE
Compare to other wire bundling methods, wireways require LESS space inside the panel.
TRUE
FALSE
What is shown in the picture?
Wire ties
wire ways
wire screw
screw terminal
What is shown in the picture?
Wire ties
wireway
wire screw
screw terminal
What is shown in the picture?
Wire ties
wire ways
wire sleeve
screw terminal
_______________ are jackets that are wrapped around the bundles of wire.
Wire ties
wire ways
wire sleeve
screw terminal
Wire sleeve are jackets that are wrapped around the bundles of wire.
TRUE
FALSE
Three common methods used for bundling wires inside electrical panels.
wireways
wire ties
wire sleeves
wire cable
Wire ways, wire ties and wire sleeves are the three common methods used for bundling wires.
TRUE
FALSE
Wire ways, wire ties and wire sleeves are NOT the three common methods used for bundling wires.
TRUE
FALSE
To wire a motor, the motor leads must be spliced to the power leads.
TRUE
FALSE
Once the leads have been spliced, they must be taped.
TRUE
FALSE
After splicing, the leads can be installed without tape.
TRUE
FALSE
In applying electrical tape, use 1 layer for every ________ volts of the insulation rating.
100 Volts
200 Volts
300 Volts
400 Volts
A 600 Volts cable insulation rating needs 6 layers of tape.
TRUE
FALSE
A 300 Volts cable insulation rating needs 2 layers of tape.
TRUE
FALSE
Separate terminal blocks are used inside the control wiring and power wiring.
TRUE
FALSE
Electrical _____________ is the process of using conductors to connect electrical sytem to earth ground.
grounding
connection
cabling
cutting
Electrical grounding is the process of using conductors to connect electrical sytem to earth ground.
TRUE
FALSE
What is the color of the grounding conductor?
green and yellow stripe
red
yellow
blue
Two type of conductors.
solid
stranded
liquid
plastic
Grounding conductors do not carry current during normal condition.
TRUE
FALSE
Grounding conductors is carrying current during normal condition.
TRUE
FALSE
Voltage and current measurement CAN be used to check the grounding circuit.
TRUE
FALSE
Voltage and current measurement CANNOT be used to check the grounding circuit.
TRUE
FALSE
The inspection of the grounding system should first include a ____________ of the ground wires.
visual check
checking of continuity
checking of voltage
checking of current
The second part of inspection inspection of the grounding system is the _______________________.
visual check
checking of continuity
checking of voltage
checking of current
When there is CONTINUITY, the DMM will produce sound.
TRUE
FALSE
When there is CONTINUITY, the DMM will NOT produce sound.
TRUE
FALSE
What do you call this earthing system?
TT
TN-S
TNC-S
IT
What do you call this earthing system?
TT
TN-S
TNC-S
IT
What do you call this earthing system?
TT
TN-S
TNC-S
IT
Earthing is important to prevent shock hazard.
TRUE
FALSE
Electrical installation without earthing system is good.
TRUE
FALSE
The 2 common methods used to run wires through conduit between electrical panels are.
fish tape
pushing by hand
electrical tape
packing tape
This device is used to pull wire through conduit
fish tape
electrical tape
masking tape
packing tape