What are lipids?
Hydrophilic
Hydrophobic
Hydrophobia
Hydrolysis
The most common analysis for Glucids is
Hextrose
Sucrose
Glucose
lactose
What is the most common anticoagulant for CC test?
EDTA
Citrate
Heparin
No correct answer
What is serum?
Liquid that remains after the blood has clotted
Liquid that remains when clotting is prevented by adding anticoagualnt
Both 1 and 2
No correct answer
What is the function of a Substrate?
To make the reaction clear
To make the reaction turbid
To make the reaction colored
To make the reaction aggregate
What is the cardiac enzyme?
HDL
ALT
LDH
GGT
What is the different between Std and Cal?
Std is more precise than Cal
Std is less precise than Cal
Std is equal to Cal
No correct answer
If control is expired, and if Internal QC is performed - one level is out of range. Can we continue to run patient samples? Select the most correct answer.
Yes
No
Yes, because another one is in range
No, because we cannot guarantee the result in case of IQC is invalid
In cases of Liver that doesn't work or not functioning enough, so
TB and DB are Increase
TB and DB are decrease
TB is increase, DB is decrease
TB is decrease, DB is increase
Which type of anticoagulant that we use for testing HbA1C?
Citrate
Heparin
EDTA
No need for anticoagulant
What is the maximum throughput of the Pentra C400?
300 tests/hour
400 tests/hour
420 tests/hour
none of the above
How many positions are in the refrigerated compartment of the PC400?
52
44
42
55
If without ISE, what is the maximum throughput of the YC 230?
120 samples/hour
200 samples/hour
300 samples/hour
400 samples/hour
Identify the difference/s between the YC 230 and YC 240
Disposable vs washable cuvette
Manual vs Automatic cuvette disposal
Manual vs Automatic Barcoding of reagents
With requirement of dedicated water system
Which Horiba Yumizen Chemistry Analyzer is FDA Certified?
Yumizen C230
Yumizen C240
Yumizen C560
all of the above
Identify the new "Horiba Pointe" reagent/s that is/are available now in the Pentra C400.
TDM
Lactate
ASO
HBA1C
Which instrument does not have a dedicated mixer?
YC 230
YC 240
YC 560
none of the above
Which of the following statement is not correct?
The Yumizen C240 uses a semi permanent glass cuvette.
The Yumizen C230 uses the same reagents as the Yumizen C240.
THe Yumizen C240 and Yumizen C560 has automatic washing of cuvette.
The Yumizen 240does not require a dedicated water station.
How many cuvettes are there in one segment of a Pentra C400 cuvette?
5
8
12
15
How many cuvette segment can you load in the Yumizen C240?
5
8
12
15