NEW
Font size
WorksheetsAAD Unit 5 Test
Total questions: 70
Worksheet time: 35mins
Foundation sections would be shown on the structural drawings.
True
False
Blueprints are made with a plotter.
True
False
Numbering systems are governed by the AIA drawing code.
True
False
Print rooms are designated areas where drawings are reproduced.
True
False
Specifications are part of the construction document package.
True
False
A document handler manages the placement and storage of construction documents.
True
False
Specifications are a necessary part of construction documentation.
True
False
Every drawing set has specifications in some form.
True
False
The individual with final say on the project is the:
Architect
Engineer
Owner
Draftsman
Dimension lines should be unbroken.
True
False
Dimension lines should be no closer than 3/8" to the object.
True
False
The preferred spacing of a dimension line away from an object is 1/2'.
True
False
Dimension lines should be spaced no closer than 3/8" from each other.
True
False
Foot & inch marks are preferred when indicating dimensions.
True
False
Centimeters are used when using the metric system.
True
False
When using the metric system, the scale & units must be indicated.
True
False
Detail drawings are generally dimensioned in inches.
True
False
Vertical dimensions should be indicated heavier than horizontal dimensions. (9-9)
True
False
Vertical dimensions are read from bottom to top.
True
False
Vertical dimensions are always placed to the left of the dimension line.
True
False
Horizontal dimension lines run left & right on the drawing.
True
False
Horizontal dimensions are always placed above the dimension line.
True
False
Horizontal dimensions are never used inside the floor plan.
True
False
Overall dimensions measure the distance of the entire floor plan.
True
False
Dimension lines should be thin and dark.
True
False
Arrowheads should be thin and light.
True
False
Always dimension to the center of walls.
True
False
If dimensioning edge-to-edge of doors or windows, dimensions are for actual door size.
True
False
Solid concrete walls are dimensioned center-to-center.
True
False
Always dimension to outside of brick or siding.
True
False
Dots shown on the end of a leader indicate only the "dot" area.
True
False
If stair sections are drawn, indicate the rise & run on the floor plan.
True
False
Door sizes should be shown on the floor plan or in a door schedule.
True
False
Window sizes should be shown on the floor plan or in a window schedule.
True
False
Schedules are preferred over indicated sizes on the drawing.
True
False
All rooms should be labeled with either a name or number or both. (9-27)
True
False
A North Arrow is not required on a floor plan.
True
False
Leader lines on sections should be drawn curved or at an angle.
True
False
Extension lines extend from the corner or edge of objects.
True
False
Dimension lines can extend beyond the extension lines.
True
False
On framed construction, overall dimensions are understood to be out-to-out of framing.
True
False
Notes should be placed only for specific major construction requirements.
True
False
It is always best to use a finish schedule over notations.
True
False
Always show general notes on plans.
True
False
A 2x4 stud is still indicated as a 2x4 on a metric drawing.
True
False
Pressure treated material should always be indicated by a note.
True
False
Notes on drawings should be very clear and concise.
True
False
Abbreviations should always be used to save time and space.
True
False
There are no standards for abbreviation use in drafting.
True
False
The typical process for numbering windows is A, B, C, etc.
True
False
Detail names or titles should be light and not overwhelm the remainder of the drawing.
True
False
Room names are not underlined.
True
False
Floor plans are the key drawings in the design set. (9-44)
True
False
Dimensions under 1'-0" are shown in inches as shown in the sketch.
True
False
What is the vent called that runs up the wall and vents out the roof?
Waste vent
V.T.R.
Stack vent
All of the options
The diameter of the vent pipe is normally:
1 1/4"
1 1/2"
1 3/4"
2"
The wall commonly known as a ______ nominal wall, is used to house a soil stack that is 4" in diameter.
4 1/2"
6"
7 1/2"
8"
Partial walls require a minimum height above the floor of ______ and are often capped with wood.
32"
36"
42"
48"
Minimum stair width is _____ but 48" to 60" is preferred if space is available.
700 mm
800 mm
900 mm
1200 mm
A clear height of _____ is the minimum amount of head room required for the length of the stairs.
5'-8"
6'-0"
6'-8"
7'-0"
Handrails must measure between _____ and _____ above the nosing.
34" and 38"
34" and 40"
36" and 38"
38" and 40"
What is the minimum crawl space or attic access required?
22x28
22x30
24x30
24x32
What is the minimum amount of slope for a concrete garage floor?
1/16"/ft
1/8"/ft
3/16"/ft
1/4"/ft
What is the recommended space of a sink from a wall?
28"
30"
32"
None of the options
What is the minimum width for a hallway?
34"
36"
42"
48"
What is used to block the flow of water vapor into a structure?
Vapor barrier
Drain pipe
PVC drain
Soil vent
What is the minimum height for a parapet?
36"
40"
42"
48"
An airspace for transporting air from the HVAC system is called:
Air return
Plenum
Ductwork
None of the options
The end of a rafter that rests on the top plate is called:
Truss
Bottom core
Heel
Top core
A wall less than full height is called: (10-16)
Party wall
Knee wall
Partition
None of the options