wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

PLC LINK & DATA MANIPULATION

Total questions: 14

Worksheet time: 7mins

Name
Class
Date
1.

The best choise to program PLC in WSMB mechatronic competition by using........

a)

Ladder diagram

b)

Mnemonic code

c)

SFC + ladder diagram

d)

Instruction list + Ladder diagram

2.

Which below the CORRECT step to do SFC using cx programming?

a)

Programs > Delete NewProgram1 > Insert Program > SFC

b)

Programs > Insert Program > SFC

c)

Programs > Delete NewProgram1 > Insert SFC

d)

Insert Program > SFC

3.

Below categorised as PLC advanced function EXCEPT?

a)

CMP

b)

SFT

c)

JUMP

d)

CNT

4.

Below the easiest way to download program from PC to CJ1M OMRON PLC

a)

CN266 link

b)

USB A to B male to male

c)

RS232 link male to male

d)

USB A to A male to female

5.

Below the easiest way to download program from PC to CJ2M OMRON PLC

a)

CN266 link

b)

USB A to B male to male

c)

USB A to A male to male

d)

RS232 link male to male

6.

Below are true about CJ2M OMRON PLC EXCEPT?

a)

Easier program downloaded via program console

b)

Easier program downloaded via PC

c)

Can be linked to PC via RS232 link

d)

Suitable for nonmobile automation project

7.

Normal application voltage for PLC i/o and electropneumatic devices is.....

a)

5V

b)

10V

c)

12V

d)

24V

8.

To connect any sensors which use operating voltage less then 24V, an interface device, X should be used. What is X?

a)

Switch

b)

Coil

c)

Relay

d)

Valve

9.

To connect any 230AC motor to PLC output, an interface device, X should be used. What is X?

a)

Solenoid

b)

Coil

c)

Relay

d)

Contactor

10.

To connect any 3 phase motor to PLC output, an interface device, X should be used. What is X?

a)

Contactor

b)

Solenoid

c)

Relay

d)

Valve

11.

Select CORRECT coding for the figure

a)

Ld A

And B

Ld C

And D

Out X

b)

Ld not A

And B

Ld C

And D

Out X

c)

Ld not A

And B

Ld C

And D

And Ld

Out X

d)

Ld not A

And B

Ld C

And D

Or Ld

Out X

12.

Select CORRECT codding for the figure

a)

Ld X000

Ld X001

And X002

Or Ld X003

Out Y000

b)

Ld X000

Or X001

Ld X002

Or not X003

And Ld

Out Y000

c)

Ld X000

Or X001

Ld X002

Or not X003

Or Ld

Out Y000

d)

Ld X000

Or X001

And Ld

Ld X002

Or not X003

Out Y000

13.

Select CORRECT codding for the figure

a)

Ld 000

Out tim 001

#30

b)

Ld 000

tim 001

#30

c)

Ld 000

And tim 001

#30

d)

Ld 000

Or tim 001

#30

14.

Select CORRECT codding for the figure

a)

Ld 000

Or 001

Out CNT 001

#20

b)

Ld 000

Or 001

CNT 001

#20

c)

Ld 000

And 001

Out CNT 001

#20

d)

Ld 000

Ld 001

CNT 001

#20