AAD Unit 6 Test

Total questions: 70

Worksheet time: 35mins

Name
Class
Date
1.

What is a term used in building codes to describe access?

a)

Exit

b)

Stair wells

c)

IRC code book

d)

Egress

2.

Outlets should average one for every ___ feet of wall space.

a)

5'

b)

12'

c)

4'

d)

6'

3.

Choose the correct door swing.

a)

A

b)

B

c)

All of the options

d)

None of the options

4.

What is the minimum clearance distance in front of a sink?

a)

19"

b)

21"

c)

22"

d)

24"

5.

In residential construction, what is the minimum width of a half bath?

a)

30"

b)

32"

c)

34"

d)

36"

6.

What is the correct symbol for a Hose Bib in the image shown?

a)

A

b)

B

c)

C

d)

D

7.

What is the correct symbol for a standard 110v/115v outlet in the image shown?

a)

A

b)

B

c)

C

d)

D

8.

Residential floor plans are always drawn at a scale of 1:50.

a)

True

b)

False

9.

1/4"=1'-0" and 1:48 scale are the same.

a)

True

b)

False

10.

The soil stack is a vertical soil pipe carrying the discharge from the toilet fixture.

a)

True

b)

False

11.

When showing stairs on a floor plan you should always show and arrow going up but not going down.

a)

True

b)

False

12.

A hearth should always have a finish elevation of 0'-0".

a)

True

b)

False

13.

The ADA codes are always used in residential drawings.

a)

True

b)

False

14.

Doorknobs on doors can be operated more easily than levers.

a)

True

b)

False

15.

GFCI outlets should be installed near any water source.

a)

True

b)

False

16.

All outside outlets do not need to be weatherproof outlets.

a)

True

b)

False

17.

Floor plans should only be drawn at 1/4"=1'-0".

a)

True

b)

False

18.

Solid concrete or block walls are dimensioned the same as wood construction. (10-34)

a)

True

b)

False

19.

Sub-dimensions must add up to overall dimensions.

a)

True

b)

False

20.

Heating and cooling equipment located in a garage must be protected from impact. This is generally done by placing what in front of the equipment?

a)

Mesh wire

b)

Cyclone fencing

c)

Steel pipe

d)

Wood fencing

21.

The minimum size door required to access HVAC equipment is:

a)

42"

b)

36"

c)

22"

d)

20"

22.

Suspended HVAC equipment must be at least ____ from the ground.

a)

6"

b)

8"

c)

10"

d)

None of the options.

23.

Factory-made ducts must be approved and labeled by:

a)

LU

b)

UL

c)

IRC

d)

RAC

24.

When ducts must be run between floors, they need to be run in a(n):

a)

Open space

b)

Insulated space

c)

Concealed space

d)

Outside

25.

If a residential or commercial structure cannot be uniformly heated or cooled from one compressor a ____system may be required.

a)

double

b)

series

c)

split

d)

parallel

26.

One type of zonal heater is:

a)

Radiator

b)

Blower

c)

Baseboard

d)

None of the options

27.

In a central heating system, the thermostat should be placed:

a)

By a door

b)

In the kitchen

c)

Close to a return air duct

d)

Near a window

28.

A fitting with a removable plug is a:

a)

Drain

b)

Fitting

c)

Cleanout

d)

Main

29.

A pipe, normally underground, that carries wastewater and refuse is a :

a)

Soil pipe

b)

Stack

c)

Sewer

d)

Trap

30.

A pipe that carries the discharge of water closets or other similar fixtures is a:

a)

Sewer

b)

Soil pipe

c)

Stack

d)

Trap

31.

Locating the water heater in an insulated space is one example of:

a)

Poor design

b)

Energy conservation

c)

Unnecessary

d)

None of the options

32.

Another name for a water closet is:

a)

Bide

b)

Toilet

c)

Unnecessary

d)

None of the options

33.

Plumbing riser diagrams are usually drawn as an:

a)

Oblique

b)

Isometric

c)

Orthographic

d)

Prospective

34.

When indicating pipe elevation, the abbreviation "BOP" stands for:

a)

Bottom of plumbing

b)

Bottom of pipe

c)

Big outside pipe

d)

Beginning

35.

Electrical installation for new construction occurs in what phases?

a)

Finish

b)

Rough-in

c)

Temporary

d)

All the options

36.

The abbreviation "AMP" stands for: (11-17)

a)

Unit measure of electrical force

b)

A measurement of electrical current flow

c)

A unit measure force

d)

None of the options

37.

A conduit is:

a)

Pipe or tube to enclose electrical conductors

b)

Person on a train

c)

Outlet box

d)

Panel

38.

Maximum distance between wall plug is:

a)

6'

b)

12'

c)

13'

d)

15'

39.

Each wall over ___ must have an outlet.

a)

2'

b)

3'

c)

4'

d)

5'

40.

Keeping outlets to a minimum at exterior walls is considered:

a)

Energy conservation

b)

Poor design

c)

Unnecessary

d)

None of the options

41.

Identify the HVAC symbol.

a)

Turning vane

b)

Corner cut

c)

90 turn

d)

None of the options

42.

Identify the symbol.

a)

Double elbow

b)

Double branched flanged elbow

c)

Y-elbow

d)

Lateral

43.

Identify the symbol.

a)

Floor outlet single

b)

Floor switch

c)

Junction box

d)

Generator

44.

Identify the symbol.

a)

Flood light

b)

Fluorescent light

c)

Yard light

d)

Can ceiling light

45.

Identify the symbol.

a)

Radio outlet

b)

Phone

c)

Vacuum

d)

Transformer

46.

Some principle parts of a refrigeration system are:

a)

Cooling coil

b)

Compressor

c)

Expansion valve

d)

All of the options

47.

The code that controls electrical circuits and plans is the:

a)

NEC

b)

NIC

c)

CIC

d)

CAB

48.

Light switches would normally be placed ___ above the floor.

a)

2'-10"

b)

3'-0"

c)

3'-4"

d)

3'-6"

49.

Identify the HVAC symbol.

a)

Supply

b)

Diffuser

c)

Return

d)

Louver opening

50.

Identify the HVAC symbol.

a)

Airline valve

b)

Solenoid valve

c)

Relief valve

d)

Automatic 3-way valve

51.

Identify the HVAC symbol.

a)

Solenoid valve

b)

Relief valve

c)

Airline valve

d)

3-way valve

52.

Identify the symbol.

a)

Elbow up

b)

Lateral

c)

Union

d)

Elbow down

53.

Identify the symbol.

a)

Gate valve

b)

Globe valve

c)

Check valve

d)

Relief Valve

54.

Identify the symbol.

a)

Gate valve

b)

Globe valve

c)

Check valve

d)

Relief Valve

55.

Identify the symbol. (11-36)

a)

Floor switch

b)

Generator

c)

Junction box

d)

Floor outlet single

56.

Heating and cooling equipment do not need to be accessible.

a)

True

b)

False

57.

HVAC equipment located on the ground should be supported on a concrete slab.

a)

True

b)

False

58.

Equipment connected to duct systems must have a temperature limit control.

a)

True

b)

False

59.

HVAC equipment installed outdoors must be listed and labeled for outdoor use.

a)

True

b)

False

60.

Ducts in unconditioned areas do not have to be insulated.

a)

True

b)

False

61.

A heat pump is a forced-air central heating and cooling system.

a)

True

b)

False

62.

A zonal heating system allows the heating of the home to family's needs.

a)

True

b)

False

63.

A zonal heating system has only one thermostat for the house.

a)

True

b)

False

64.

A central heating system requires using all the heat produced.

a)

True

b)

False

65.

Industrial piping is used to carry liquids and gases used in the manufacture of products.

a)

True

b)

False

66.

Residential piping is called plumbing.

a)

True

b)

False

67.

Using a low-flow shower head is a good example of energy conservation.

a)

True

b)

False

68.

The only plumbing items shown on the floor plan are fixtures.

a)

True

b)

False

69.

There should be at least one ceiling outlet for every two cars in a garage.

a)

True

b)

False

70.

Smoke detectors are required in all bedrooms rooms.

a)

True

b)

False