wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

National Plumbing Code - Pipe & Fittings

Total questions: 12

Worksheet time: 6mins

Name
Class
Date
1.

Where can T Fittings be used?

a)

In a Drainage System

b)

In a Venting System

c)

In both a Drainage or Venting System

d)

None of the above

2.

Where can a Cross Fitting be Used?

a)

In a Drainage System

b)

In a Venting System

c)

In both Drainage and Venting Systems

d)

None of the above

3.

Where can a Sanitary Tee (TY) fitting be used?

a)

In a nominally horizontal position

b)

In a nominally horizontal position unless used for a vent

c)

In a nominally vertical position

d)

none of the above

4.

Where can a double Sanitary T fitting be used?

a)

In a nominally horizontal position

b)

For connecting back outlet water closets installed back to back

c)

For connecting 2 urinals where a cleanout fitting is provided above the connection

d)

In a nominally vertical position connecting branches, or vent pipes.

5.

When can a short radius (regular) 90 degree elbow less than 4 inch in size be used to connect 2 soil-or-waste pipes?

a)

to change the direction of piping from horizontal to vertical in the direction of flow

b)

where a trap arm enters the wall

c)

connect a trap arm to a water closet

d)

all of the above

6.

When shall a long radius 90 degree elbow be used?

a)

To join 2 soil-or-waste pipes

b)

To change the direction of piping from vertical to horizontal, in the direction of flow

c)

To change the direction of piping from horizontal to horizontal, in the direction of flow

d)

All of the above

7.

Wye fittings are allowed to be used to connect to a trap arm?

a)

True

b)

False

8.

Where can Wye Fittings be used?

a)

Anywhere in a drainage system, except for trap arms

b)

Anywhere in a venting system

c)

All of the above

d)

None of the above

9.

What does every length of pipe and fitting must have cased, stamped or indelibly marked on it?

a)

Maker's Name or Mark

b)

Weight, Class or Quality of the product

c)

All of the above

d)

None of the above

10.

What is the minimum Trap Seal Depth?

a)

18 mm

b)

28 mm

c)

38 mm

d)

48 mm

e)

50 mm

11.

What is the minimum Trap Seal Depth specifically for Acid waste systems?

a)

18 mm

b)

28 mm

c)

38 mm

d)

48 mm

e)

50 mm

12.

Except for a floor-mounted service sink, every trap that serves a lavatory, a sink or a laundry try shall

a)

be provided with a cleanout plug located at the highest point of the trap or be designed so that part of the trap can be removed for cleaning purposes.

b)

be provided with a cleanout plug located at the lowest point of the trap or be designed so that part of the trap can not be removed for cleaning purposes.

c)

be provided with a cleanout plug located at the highest point of the trap or be designed so that part of the trap can not be removed for cleaning purposes.

d)

be provided with a cleanout plug located at the lowest point of the trap or be designed so that part of the trap can be removed for cleaning purposes.