1.

What is the Image shown

a)

Still

b)

Air Separator

c)

Bypass valve

d)

Slimline Boiler

2.

What is Delta T

a)

Weight of the cistern

b)

The pump speed

c)

Room temperature divided by boiler temperature

d)

The difference between the temperature of the radiator and the room

3.

What is this

a)

Radiator spanner

b)

Sonic screwdriver

c)

Tap wrench

d)

Pump adjustment key

4.

Which radiator is a double panel double convector

a)
b)
c)
d)
5.

Balancing a heating system requires you to adjust what

a)

The thermostat

b)

The TRV

c)

The lock shield

d)

The thermometer

6.

Where is the neutral point

a)

At the edge of the Klingon empire

b)

Where the open vent connects to the circuit

c)

Where the primary flow becomes the return

d)

Where the cold feed connects to the circuit

7.

The main problem with the one pipe system is that

a)

They are prone to blockages

b)

They can't be used in a bungalow

c)

They are expensive to run

d)

The earlier radiators pass cooler water back into the circuit

8.

Wiring diagrams for the heating controls on a fully pumped system can be found in the

a)

Manufacturer’s Instructions

b)

British Standards

c)

NICEIC standards

d)

Wiring Regulations.

9.

The cold water supply to a fully pumped open vented central heating system should be

isolated at the

a)

stop valve to the incoming cold water supply pipework

b)

Gate valve on the cold feed pipework from the F & E cistern

c)

service valve to the float operated valve to the CWS cistern

d)

service valve to the float operated valve to the F & E cistern.

10.

Which one of the following gas boilers overcomes the need for a cold water storage cistern,

feed and expansion cistern and hot water storage vessel?

a)

Back-boiler.

b)

Condensing.

c)

Combination.

d)

Room-heater.

11.

When positioning a single room thermostat, it’s recommended height from ground level is

a)

1m

b)

1.5m

c)

2m

d)

2.5m

12.

When setting the water level in a feed and expansion cistern, the allowance that should be

made for the expansion of water in the heating system is

a)

4 %

b)

6 %

c)

10 %

d)

1600 times its volume

13.

If TRVs or zone valves on a system close, the purpose of the automatic by-pass valve is to

make sure that

a)

water can flow through the cylinder

b)

air cannot enter the heating system

c)

water cannot pump over the vent

d)

water can flow through the boiler

14.

The recommended test pressure for a hydraulic test on a central heating system is

a)

normal working pressure

b)

1.5 times normal working pressure

c)

twice the normal working pressure

d)

3 bar pressure

15.

Before isolating a heating system for the day, in cold weather, in a flat owned by an elderly

person, a plumber should

a)

get on with the work as fast as possible

b)

ensure that an alternative means of heating is available

c)

only carry out the work if two plumbers are available

d)

refuse to carry out the job at all costs.

16.

Gas Boilers should be installed by someone registered with

a)

Gas Safe

b)

HETAS

c)

OFTEC

d)

Ofsted

17.

Oil Fired Boilers should be installed by someone registered with

a)

Gas Safe

b)

HETAS

c)

Ofsted

d)

OFTEC

18.

Solid Fuel Boilers should be installed by someone registered with

a)

Gas Safe

b)

OFTEC

c)

Ofsted

d)

HETAS

19.

What is the image shown used for?

a)

Clearing the pump

b)

Venting the boiler interlock

c)

Charging the radiators

d)

Bleeding the radiators

20.

What is this

a)

TRV

b)

Bypass valve

c)

Thermostatic mixing valve

d)

High temperature relief valve