wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

2365-203 Electrical Installation

Total questions: 40

Worksheet time: 20mins

Name
Class
Date
1.
TNS earthing systems use the
a)
supply cable armour
b)
earth electrode
c)
neutral
d)
transformer
2.
RCD's that are used to protect socket outlet are rated at
a)
30 A
b)
30 mA
c)
3 mA
d)
300 mA
3.
The symbol Ze is associated with
a)
total loop impedance
b)
external suppliers earth loop impedance
c)
R1
d)
R2
4.
A TNCS earthing system, changes Line to c.p.c faults to
a)
Line to neutral faults
b)
Line to Line faults
c)
Line to c.p.c faults
d)
c.p.c to Line faults
5.

The symbol for Total earth loop impedance is?

a)

Zs

b)

Ib

c)

Iz

d)

Ze

6.

The insulation material in mineral insulated cable is

a)

manganese oxide

b)

magnesium dioxide

c)

manganese dioxide

d)

magnesium oxide

7.

What is the maximum percentage of trunking that can be filled with cable:

a)

35%

b)

45%

c)

55%

d)

65%

8.
Which MCB will disconnect in the shortest time?
a)
Type C
b)
Type D
c)
Type B
d)
RCD
9.
What is the BS number for a MCB?
a)
BS 60898
b)
BS 1265
c)
BS 61009
d)
BS 60947
10.
Name the extraneous conductive part
a)
Socket cover
b)
PVC switch
c)
Central heating pipework
d)
Cable tray
11.
Identify the exposed conductive part.
a)
PVC conduit
b)
Metal trunking
c)
Ventilation ductwork
d)
oil pipes
12.
which conductor links the MET to an exposed conductive part>
a)
Bonding conductor
b)
Supplementary bonding
c)
Earthing conductor
d)
CPC
13.
which earthing system requires an earth electrode?
a)
TNC
b)
TNS
c)
TN-C-S
d)
TT
14.
Identify the Transmission voltage (super grid voltage)
a)
11Kv
b)
33Kv
c)
400Kv
d)
230v
15.
Which energy production uses high pressure steam to power a generator?
a)
Wind
b)
Hydro
c)
Nuclear
d)
PV
16.
Which one of the following are non-statutory regulations?
a)
Electricity at Work Regulation
b)
Manual Handling Regulation
c)
BS 7671
d)
Provision and use of Work Equipment Regulations
17.
The document showing the location of electrical equipment in an electrical installation is a:
a)
specification
b)
drawing 
c)
variation order
d)
gannt chart
18.
Which one of the following diagram types does not show individual conductors or cables but shows the sequence of equipment
a)
Block
b)
Circuit 
c)
Schematic 
d)
Bar chart
19.
The type of trunking that can be used as a circuit protective conductor is:
a)
mini  
b)
PVC dado
c)
steel
d)
plastic
20.
A circuit installed to supply a fire panel would be identified as:
a)
power and heating
b)
data communication
c)
control circuit
d)
alarm and emergency system
21.

Which one of the following directly affects all persons working with electricity in a working environment?

a)

Electricity Safety, Quality and Continuity Regulations

b)

BS 7671:2018

c)

Electricity at Work Regulations

d)

Construction design and management Regulations

22.

A drawing is produced to a scale of 1:50 showing a socket outlet installed 3.5cm from the corner of a room. Which one of the following is the actual distance from the corner in the room?

a)

0.875m

b)

1.75m

c)

3.5m

d)

7m

23.

Which one of the following symbols represents the rating factor for thermal insulation

a)

Ci

b)

Ca

c)

Cf

d)

Cg

24.

Which one of the following devices is suitable for an installation supplying an Xray machine in a hospital?

a)

BS 3036 rewireable fuse

b)

BS EN 60898 Type D

c)

BS EN 60898 Type C

d)

BS EN 60898 Type B

25.

Which one of the following is the minimum conduit size suitable for a short straight run containing the following stranded cables: 4x1.5mm^2 and 3x2.5mm^2?

a)

16mm

b)

20mm

c)

25mm

d)

32mm

26.

Which one of the following is the conduit capacity factor to be used where a 25mm conduit has 2 bend in a 6m run?

a)

111

b)

182

c)

333

d)

600

27.

Which one of the following is the correct name of the component which links the main earthing terminal of an installation to the means of earthing?

a)

Main protective bonding conductor

b)

Supplementary equipotential bond

c)

Earthing conductor

d)

Functional earth

28.

What is represented by Zs in the following formula: Zs=Ze+(R1+R2)?

a)

Total earth fault loop impedance

b)

External earth fault loop impedance

c)

Final circuit earth fault loop impedance

d)

Combined resistance of the earth path

29.

What is represented by Ze in the following formula: Zs=Ze+(R1+R2)?

a)

Total earth fault loop impedance

b)

External earth fault loop impedance

c)

Final circuit earth fault loop impedance

d)

Combined resistance of the earth path

30.

What is represented by R1 in the following formula: Zs=Ze+(R1+R2)?

a)

Resistance in the line conductor

b)

Resistance in the earth conductor

c)

Total earth fault loop impedance

d)

External earth fault loop impedance

31.

Which one of the following is an exposed conductive part?

a)

Metal-clad switch

b)

Structural steelwork

c)

Air conditioning ducting

d)

Metallic oil service pipe

32.

Which one of the following is metal cable trunking?

a)

Earthed conductive part

b)

Extraneous conductive part

c)

Insulated part

d)

Exposed conductive part

33.

Which one of the following is an extraneous conductive part?

a)

Metallic gas service pipe

b)

Metal-clad twin socket outlet

c)

Heavy duty steel conduit

d)

PVC mini-trunking

34.

Which one of the following methods of generating electricity uses fossil fuels?

a)

Wave power

b)

Solar

c)

Gas

d)

Wind

35.

Which one of the following uses sunlight to generate electricity?

a)

Photo-voltaic

b)

Biomass

c)

Wind

d)

Air source heat pump

36.

Which one of the following is a transmission voltage?

a)

400kV

b)

33kV

c)

11kV

d)

400V

37.

Which one of the following is a typical distribution voltage for a medium-sized factory where a private sub-station is located?

a)

230V

b)

400V

c)

5kV

d)

11kV

38.

Which one of the following describes the process of a solar photo-voltaic system?

a)

Solar power is used to ignite a biomass which heats up water

b)

Solar power is collected by a solar panel which provides electricity

c)

Solar power is collected by a solar panel which provides hot water

d)

Solar power causes hot air to rise, rotating a generator that produces electricity

39.

State the protective device rating for an A3 radial final circuit.

a)

20A

b)

32A

c)

30A

d)

6A

40.

The number of outlets that can be connected to an A1 ring final circuit is unlimited provided that the floor area served does not exceed:

a)

100m^2

b)

75m^2

c)

50m^2

d)

25m^2