1.

Which of the following requires 220/240 volt electrical current?

a)

Refrigerator

b)

Freezer

c)

Clothes Dryer

d)

Washing Machine

2.

GFCI stands for:

a)

Ground fault circuit interrupter

b)

Grounded for circuit interference

c)

Ground for ceiling installation

d)

Grounded for common inference

3.

A single pole switch can control a light or group of lights from how many locations?

a)

1

b)

2

c)

3

d)

4

4.

A single pole switch can control a light or group of lights from how many locations?

a)

1

b)

2

c)

3

d)

4

5.

Controlling one light from 3 separate locations requires:

a)

3 single-pole switches

b)

Two 3-way switches and a 4-way switch

c)

Two 3-way switches

d)

Such an arrangement is not possible

6.

An electrical safety switch that opens a circuit when excessive amperage occurs is called a:

a)

Fuse

b)

Breaker

c)

Meter

d)

None of the options

7.

The measurement of electrical flow is called the:

a)

Ampere

b)

Volt

c)

Watt

d)

Current

e)

None of the options

8.

The meter base should be mounted so the meter socket is preferably:

a)

On the exterior of the house on the side of the garage

b)

On the exterior of the house on the back

c)

On the interior of the garage

d)

On the exterior of the house next to the entrance

e)

None of the options

9.

A ground is an electrical connection to:

a)

The meter

b)

The earth via a rod

c)

The outlet

d)

The breaker

10.

Ground-fault circuit interrupters:

a)

Trip a circuit breaker when there is any unbalance in the circuit current

b)

Are required for any electric fixture within 6'-0" (1820 mm) of water

c)

Are needed in kitchens, bathrooms, and outdoors

d)

All of the options

11.

Identify the electrical symbol.

a)

Open outlet

b)

Exit light outlet

c)

Lamp holder

d)

Lighting outlet

12.

Identify the electrical symbol.

a)

Ceiling switch

b)

Junction box

c)

Just a circle

d)

Ceiling junction box

13.

Identify the following electrical wiring symbol.

a)

Ceiling Outlet / Box

b)

Fire Alarm Outlet

c)

Fan Outlet

d)

Free - Non Used Ceiling Outlet

14.

Identify the following electrical wiring symbol.

a)

Lamp Outlet with additional Power

b)

Lamp Outlet with Push Switch

c)

Lamp Outlet

d)

Lamp Outlet with Pull Switch

15.

Identify the electrical symbol. (12-14)

a)

Ceiling Junction Box

b)

Joint Use Outlet

c)

Wall Junction Box

d)

None of the options

16.

Identify the following electrical wiring symbol.

a)

Telephone

b)

Thermostat

c)

Telegraph

d)

Internet

17.

Identify the electrical symbol.

a)

Telephone Outlet

b)

Emergency Exit Light

c)

Wall Mounted Double Light

d)

Duplex Outlet

18.

Identify the following electrical wiring symbol.

a)

Smoke Detector

b)

Floor Duplex Outlet

c)

Single Outlet

d)

Spot Lighting

19.

Identify the following electrical wiring symbol.

a)

Weather Resistant Duplex Outlet

b)

Outlet with 2 wires only

c)

Direct Wired Outlet

d)

Outlet - Reverse Wired

20.

Identify the following electrical wiring symbol.

a)

3 Wire Special Outlet

b)

3 - Duplex Outlets

c)

Triple Outlet

d)

Outlet on 3 way switch

21.

Identify the following electrical wiring symbol.

a)

Outlet connected to a switch

b)

Single outlet

c)

Outlet mounted on side

d)

Standard outlet

22.

Identify the following electrical wiring symbol.

a)

Main Power Panel

b)

Secondary Power Panel

c)

Lighting Panel

d)

Telephone Box

23.

Identify the following electrical wiring symbol.

a)

Lighting Panel

b)

Telephone Box

c)

Secondary Power Panel

d)

Main Power Panel

24.

Identify the following electrical wiring symbol.

a)

Special Purpose Outlet

b)

Telephone

c)

Internet

d)

Digital TV

25.

Identify the following electrical wiring symbol.

a)

Telephone

b)

Wall Mounted Fixture

c)

Internet

d)

Digital TV

26.

Identify the following electrical wiring symbol. (12-25)

a)

Welder Outlet

b)

Air Conditioner Outlet

c)

Range Outlet

d)

Microwave Outlet

27.

Identify the following electrical wiring symbol.

a)

Electrical Conduit

b)

Hidden Line

c)

Dotted Line

d)

Switch Wire

28.

Identify the following electrical wiring symbol.

a)

Lamp Post

b)

Conduit with Turn Down

c)

Power Post

d)

Conduit with Turn Up

29.

Identify the following electrical wiring symbol.

a)

Lamp Post

b)

Conduit with Turn Up

c)

Power Pole

d)

Conduit with Turn Down

30.

Identify the following electrical wiring symbol.

a)

Three-Way Switch

b)

Single Pole Switch

c)

Weatherproof Switch

d)

Tamper Proof Switch

31.

A Three-Way switch can control a light or group of lights from how many locations?

a)

1

b)

2

c)

3

d)

4

32.

Double pole switches are typically used for:

a)

Switch receptacles and appliances using 240 volt circuits

b)

Controlling two lights from one location

c)

Switch between circuits

d)

None of the options

33.

Identify the following electrical wiring symbol.

a)

Double Pole Switch

b)

Single Pole Switch

c)

Three Way Switch

d)

Key Operated Switch

34.

Identify the following electrical wiring symbol.

a)

Key Operated Switch

b)

Three Way Switch

c)

Single Pole Switch

d)

Double Pole Switch

35.

Identify the following electrical wiring symbol.

a)

Key Operated Switch

b)

Double Pole Switch

c)

Three Way Switch

d)

Single Pole Switch

36.

Identify the following electrical wiring symbol.

a)

Single Pole Switch

b)

Key Operated Switch

c)

Double Pole Switch

d)

Three Way Switch

37.

Receptacles in a bath must be GFI.

a)

True

b)

False

38.

The first phase of electrical installation is the rough-in.

a)

True

b)

False

39.

Electrical drawings are always drawn on separate sheets.

a)

True

b)

False

40.

Exterior walls should be used as much as possible for outlets because of the ease of construction.

a)

True

b)

False

41.

The electrical circuit line should not be drawn with a French curve.

a)

True

b)

False

42.

The maximum distance between outlets should be 4 inches.

a)

True

b)

False

43.

Any wall over two feet in length should have an outlet.

a)

True

b)

False

44.

Kitchens require an outlet for every 6' of counter space.

a)

True

b)

False

45.

Structured wiring systems do not use series circuits because they degrade the communication signal.

a)

True

b)

False

46.

Light switches should be placed 3' above the floor to accommodate children and people in wheelchairs.

a)

True

b)

False

47.

In hallway, ceiling lights should be placed no more than 10" apart.

a)

True

b)

False

48.

Commercial projects tend to incorporate plans with dimensions and electrical applications together for convenience.

a)

True

b)

False

49.

A Four-Way switch can control one or more lights from 4 locations.

a)

True

b)

False

50.

HVAC stands for:

a)

Home venting and cooling

b)

Heating, ventilation, and air conditioning

c)

Home ventilation and alternate cooling

d)

Home vacuum and cleaning

51.

Air supply registers are typically placed:

a)

On the ceiling above windows

b)

On the ceiling along an interior wall

c)

On the floor along an interior wall

d)

On the floor below the windows

52.

The best location for a thermostat is near:

a)

The front door for convenience and exterior wall

b)

The return air register

c)

The supply air register

d)

None of the options

53.

The unit measure of heat is the:

a)

Grain

b)

R factor

c)

BTU

d)

U factor

54.

The rate of air flow will be noted on the plans by abbreviation:

a)

AFR

b)

WA

c)

RA

d)

CFM

55.

Air-to-air heat exchangers are best suited for:

a)

Highly insulated structures with vapor barriers

b)

State-of-the-art radiant heating systems

c)

Older homes with radiator systems

d)

All of the options

56.

Air conditioning systems need compressors primarily:

a)

To circulate the conditioned air through a central forced-air system

b)

To change the temperature of the refrigerant

c)

To circulate refrigerant through the compressor system

d)

None of the options

57.

A duct label 22/12 is:

a)

22 square inches in cross-section

b)

12 inches deep

c)

12 inch diameter - 22 inches long

d)

22 inches wide

58.

An appropriate scale for an HVAC detail is:

a)

1" = 1'-0" (roughly 1:10)

b)

1/4" =1'-0" (1:50)

c)

6"=1'-0" (4:2)

d)

None of the options

59.

A 2000 square foot house with nine foot ceilings requiring a 0.5 ACH will need to exchange how many cubic feet of air per minute?

a)

17

b)

150

c)

300

d)

9000

60.

Return Air Filters should be replaced how often?

a)

Weekly

b)

Monthly

c)

Quarterly

d)

Yearly

61.

Identify the item shown.

a)

Structural lumber

b)

An opening

c)

Supply duct

d)

Return duct

62.

Identify the item shown.

a)

Structural lumber

b)

Return duct

c)

Supply duct

d)

An opening

63.

Identify item "AA."

a)

Up Lift Indicator

b)

Upper Duct Level

c)

Air Flow Direction

d)

None of the options

64.

Identify item "BB."

a)

Tape

b)

Turn

c)

Weld

d)

Turning Vanes

65.

Identify item "CC."

a)

Return Down

b)

Return Up

c)

Opening

d)

Vent

66.

Identify item "DD."

a)

Return Down

b)

Return Up

c)

Opening

d)

Vent

67.

Identify item "EE."

a)

Min / Max Air Flow

b)

Temperature Loss - Gain

c)

Duct Size

d)

Min / Max Metal Gauge

68.

When a Split Unit is used, the Heating Unit is located where?

a)

Inside

b)

Outside

c)

On the roof

d)

All of the options

69.

When a Split Unit is used, the Condenser Unit is located where?

a)

In the basement

b)

On the roof

c)

Inside

d)

Outside

70.

When a Package Unit is used, what does this indicate?

a)

No duct is required

b)

Can be placed "inside" in a central location

c)

Everything is outside except the duct

d)

All of the options

71.

Which of the following can be considered a Heating Supply System?

a)

Clothes Dryer

b)

Sun Room

c)

Washing Machine

d)