Font size
WorksheetsAtomic Absorption Spectroscopy
Total questions: 14
Worksheet time: 1hrs 1mins
The transformation of a liquid into spray of small droplets of aerosols is called (a) .
Select the process occuring during atomization
desolvation
nebulization
combustion
volatilization
There are 2 types of burners in flame spectroscopy
Spark burner
Turbulent burner
Continuum burner
Premix burner
Give the type of this AAS.
(a)
Explain why source modulation is employed in AAS.
to eliminate interference caused by emission of the
radiated flame from analyte atoms and flame gas
species.
to tune the monochromator to a different spectral line for the element of interest so that there is no overlap.
to distinguish between the component of radiation
arising from the source and the component of
radiation arising from the flame background.
Radiation source in AAS is a ___________ which provide narrow emission bands
continuum source
line source
Common radiation source for line source used in AAS
Spark or arc ablation
Hollow cathode lamp (HCL)
Electrodeless discharge lamp (EDL)
Interference: is the presence of substance that changes the signal from the analyte of interest when analytes concentration remain the same. List 3 interferences in AAS.
Ionization interference
Spectral interference
Chemical interference
Fundamental interference
What is spectral interference?
any physical process that effects the light intensity at the analytical wavelength
some ions will be produced in hot flames
alteration in analyte absorbance caused by chemical processes during atomization
In analysis of Ca using Atomic Emission Spectroscopy, the presence of sulphate ions and phosphate ions prevent the atomization of Ca2+ by forming non volatile salts. Name the type of interference described above.
spectral interference
chemical interference
ionization interference
Methods to cure the spectral interference.
Zeeman background correction
Tune the monochromator to a different spectral line for the element of interest so that there is no overlap.
Adding lanthanum chloride (LaCl3) to samples, standards and blank
In the analysis of potassium in blood samples, it is recommended that the solutions used contain 1000 ppm of CsCl. Give the function of the CsCl solution.
(a)
Methods to prevent chemical interferences.
Add ionization suppressor
Add protective agents such as EDTA.
Use a higher flame temperature.
Formation of compounds between the metal and other components in flame. Choose the correct interference.
Spectral interference
Ionization interference
Chemical interference