WorksheetsProcess Instru Quiz 2
Total questions: 4
Worksheet time: 3mins
A meter reads 115.50 V and the true value of the voltage is 115.44 V. Determine the static error, and the static correction for this instrument.
+0.06 V
-0.06 V
+0.03 V
-0.12 V
A thermometer reads 71.5 deg C and the static correction given is +0.5 deg C. Determine the true value of the temperature.
72.5
72
71.5
71
A thermometer is calibrated for the range of 100 deg C to 150 deg C. The accuracy is specified within +/-0.25 percent. What is the maximum static error?
+/-0.125 percent
+/-0.25 percent
+/-0.05 percent
+/-0.5 percent
An analogue indicating instrument with a scale range of 0 - 2.50 V shows a voltage of 1.46 V. A voltage has a true value of 1.50 V. Find the values of absolute error and correction and Express the error as a fraction of the true value and the full scale deflection.
-0.123%
-1.23%
-0.266%
-2.66%