wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Control systems I(Viscosity controller & OMD)

Total questions: 20

Worksheet time: 11mins

Name
Class
Date
1.

Centistokes is the unit to used to indicate

a)

Oil mist level

b)

pressure

c)

Viscosity

d)

None of the above

2.

A HFO 180 grade fuel has a viscosity _______________ 180 Cst at 50o C.

a)

equal to or less than

b)

Greater than

c)

Exactly equal to

3.

The gear pump maintains a ___________ flow through the capillary arrangement to find the pressure difference as a measure of viscosity.

a)

Turbulent

b)

Laminar

c)

Axial

d)

All of the above

4.

Normally, the output signal from the viscosensor is connected to _____________________.

a)

Flapper nozzle of the viscosity controller

b)

a 3 way solenoid valve

c)

measured value bellow of the viscosity controller

d)

None of the above

5.

When the set value and measured viscosity values are same, the pneumatic controller makes the 3 way valve position

a)

to remain same and more of the steam bypasses the heater

b)

to open and more steam is supplied to the heater

c)

to open and more of the steam bypasses the heater

d)

to remain same and more steam is supplied to the heater

6.

If the measured value of viscosity decreases when compared to the set value, the fuel oil has to be

a)

Cooled

b)

Heated

c)

Stopped

d)

None of the above

7.

How may piezo elements are used in a vibration type of viscosity sensor?

a)

5

b)

4

c)

3

d)

2

8.

In a high viscosity medium, the resonance frequency slightly shifts towards lower frequencies.

The statement is True or False (type it)

(a)  

9.

If the viscosity of the fuel oil and its viscosity index are on the higher side, it leads to

a)

poor combustion inside the engine cylinder

b)

Good combustion in the engine cylinder

c)

None of the above

10.

The 3 way valve for temperature(Viscosity) control of fuel oil is controlled by

a)

Pneumatic controller

b)

Hydraulic controller

c)

Both the above

d)

None of the above

11.

What is the status of viscosity control and temperature control from this SCADA monitor?

a)

Both in ON state

b)

OFF and ON state respectively

c)

Both in OFF state

d)

ON and OFF state respectively

12.

What is the error value in the viscosity control system with the values shown in the display?

a)

0.1

b)

-0.1

c)

Zero

d)

None of the above

13.

1 ppm is equal to

a)

1 g/l

b)

1 g/ml

c)

1 mg/l

d)

1 kg/ml

14.

An oil mist detection by OMD may be used to

a)

Turn ON oil mist alarms only

b)

Turn OFF engine only

c)

Reduce the speed of the engine to half

d)

Any or some of the above depending on oil mist level detected

15.

Oil mist levels from engine cylinders are detected at

a)

Engine control room

b)

using detecting heads placed in engine room

c)

Inside Engine cylinders

d)

All the above

16.

More opacity offered in measuring chamber refers to

a)

low oil mistlevels

b)

High oil mist levels

c)

None of the above

17.

High oil mist levels may lead to

a)

Good engine performance

b)

Crankcase explosion

c)

Both the above

d)

None of the above

18.

Photo electric sensor is used in

a)

Viscosity controller

b)

Oil mist detector

c)

Both VC and OMD systems

d)

None of the above

19.

The status of Oil mist detector is communicated to remote monitoring device located in ________________.

a)

Engine room

b)

Engine control room

c)

Bridge

d)

All the above

20.

Which of the following panel display indicates high oil mist detetction?

a)
b)
c)
d)

None of the above