Ch 10 Dental Radiology Quality Assurance

Total questions: 16

Worksheet time: 8mins

Name
Class
Date
1.

Calibration of dental x-ray equipment can be performed by a dentist, dental hygienist, or dental assistant.

a)

True

b)

False

2.

Annual tests for dental x-ray machines can be performed by a dentist, dental hygienist or dental assistant

a)

True

b)

False

3.

For quality control purposes, each new box of unopened film should be tested for film freshness and fogging before it is used.

a)

True

b)

False

4.

After processing, fresh film that has been properly stored and protected will appear _________.

a)

fogged

b)

clear with a slight blue tint

c)

clouded with a blue tint

d)

totally black

5.

After performing the screen-film contact test, a wire mesh image of uniform density appears. These results indicate

a)

adequate film-screen contact

b)

inadequate film-screen contact

6.

When functioning properly, a viewbox should emit a uniform and intense light.

a)

True

b)

False

7.

One of the most critical areas of quality control that requires daily monitoring is ___________.

a)

examination of the fluorescent bulbs inside the viewbox

b)

cleaning the extraoral intensifying screens

c)

examination of the darkroom for light-tightness

d)

processing of films

8.

The coin test is used to check ___________.

a)

proper safelighting

b)

strength of the processing solutions

c)

film density

d)

beam collimation

9.

The following must be closely monitored with manual processing techniques.

a)

temperature of the water bath

b)

levels of the processing solutions

c)

accuracy of the timer

d)

accuracy of the thermometer

e)

all of the answers are correct

10.

On average, processing solutions should be replenished:

a)

once daily

b)

once weekly

c)

every 3-4 weeks

d)

every 8-10 weeks

e)

every 3-4 months

11.

On average, processing solutions should be replenished

a)

once daily

b)

once weekly

c)

every 3-4 weeks

d)

every 8-10 weeks

12.

Fresh films and fresh chemicals must be used when preparing reference radiographs.

a)

True

b)

False

13.

A reference radiograph is used to check ___________.

a)

proper safelighting

b)

light-tightness of the darkroom

c)

strength of the fixer solution

d)

strength of the developer solution

14.

If the densities of the daily image appear lighter than the densities of the reference radiograph: this would indicate that __________.

a)

the developer is too weak

b)

the developer is too concentrated

c)

the developer is too cold

d)

either a or c

15.

The clearing test is used to monitor __________.

a)

developer strength

b)

fixer strength

c)

accuracy of the timer

d)

film density

e)

none of the answers are correct

16.

Regardless of who is actually exposes the patient to radiation, the dentist is ultimately responsible for the diagnostic quality of all dental images.

a)

True

b)

False