wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

8202-35 Sanitation Examination Mock Test

Total questions: 31

Worksheet time: 40mins

Name
Class
Date
1.

The lowest connection to the soil stack on ‘low-rise’ buildings (two storeys) is _______mm from the drain invert level.

2.

The connection to the soil stack on ‘multi-storey’ buildings (more than two storeys) is _______mm from the drain invert level.

3.

State the maximum length of a 32mm waste pipe outlet from a washbasin with no bends that connect to a primary ventilated stack.

(a)  

4.

Which part of the Building Regulations deals with foul water drainage?

(a)  

5.

What type of traps are most suitable for appliances connected to a primary ventilated soil stack?

(a)  

6.

Can the waste pipe diameter be reduced at the outlet of a trap?

(a)  

7.

Name the British Standard for gravity drainage systems inside buildings

(a)  

8.

What type of bends should be avoided at the base of a soil stack?

(a)  

9.

What is AAV an acronym for?

a)

air attenuation void

b)
air admittance valve
c)

air acceptance valve

d)

air assist valve

10.

Stub stacks are only allowed to be installed where they are connected to a ventilated discharge stack or drain within ____ metres of the base of the stack.

11.

How often does a cesspit need emptying?

(a)  

12.

Name the item in the photo.

(a)  

13.

What type of test does Approved Document H of the Building Regulations recommend on an above ground sanitary pipework system?

(a)  

14.

At what pressure is a soundness test carried out and what is the medium used?

(a)  

15.

When dealing with an failure of a macerator pump for a WC what is the primary document a plumber should refer to?

(a)  

16.

What Building Regulation must sanitation systems comply with? (a)  

Choose from the below words
Part G
Part L
Part F
Part H
17.

If you are a member of a Certification Scheme and you complete your commissioning paperwork for a job. How many days do you have to submit your documents?

a)

Seven

b)

Fourteen

c)

Thirty

d)

Within Three Months

18.

Soundness Testing must comply with?

a)

BS 1212

b)

BS 12056-2

c)

BS 1056

d)

EN BS 9002-1

19.

•What is the minimum amount of water that must be left in a trap seal after performance testing?

(a)  

20.

Reasons for loss of tap/trap seal.


Tick all answers below that are correct.

a)

self-siphonage

b)

Electrolytic action

c)

Induced siphonage

d)

Compression

e)

Momentum

21.

What is shown in the image?

a)

P Trap

b)

S Trap

c)

Waterless Trap

d)

Bradley Trap

22.

British Standard BS EN 12056 contains important information regarding?

a)
Design requirements
b)

Energy Conservation

c)

safety legislation

d)

Noise limitations

23.

Manufacturers Instructions give information and guidance on?

a)

Installation

b)

fault-finding

c)

Price

d)

Precautions

e)

Component parts

24.

On routine checks of a WC macerator what should be checked?

a)

fuse rating

b)

filters

c)

valves

d)

flow rates

e)

cleaning system components

25.

What is generally found inside an Air Valve on a WC Macerator?

(a)  

26.

If a kitchen sink was installed on a long independent branch pipe and there were regular reports of ingress of foul smells, the problem could be ?

a)

AAV

b)

Spill over

c)

self -nduced siphonage

d)

incomplete commissioning form

27.

What could happen if an AAV suitable for internal use is located externally?

​ (a)  

Choose from the below words
Dry out
Over fill
Freeze
Make noise
28.

The Specification for safety of household and similar electrical appliances is found in ?

a)

BS EN 60335-2-16

b)

BS EN 12056

c)

BS 6700

d)

BS EN 1212-8:2000

29.

Match the following from the Building Regulations

a)

PART H

1.

Drainage and waste disposal

b)

PART G

2.

Sanitation, hot water safety and water efficiency

c)

PART F

3.

Means of ventilation

30.

According to Building Regulations Part H and BS12056 Part 2, what is the minimum dimension from the lowest connection to the drain invert level? For low-rise buildings up to two storeys.

a)

450mm

b)

750mm

c)

350mm

d)

1200mm

31.

Drag each tab to the correct location on the image