EE 111 - MIDTERM EXAM

Total questions: 40

Worksheet time: 25mins

Name
Class
Date
1.

The value of current, time, or both, at which an adjustable circuit breaker is set to trip

a)

Inverse time

b)

Setting

c)

Instantaneous time

d)

Concealed

2.

A device that establishes an electrical connection to the earth

a)

Grounding Electrode Conductor

b)

Grounding Conductor

c)

Grounding Electrode

d)

Conductor Grounding

3.

A conductor having no covering or electrical insulation whatsoever

(a)  

4.

A load where the maximum current is expected to continue for 3 hours or more.

a)

Over load

b)

Under load

c)

Continuous Load

d)

Loads

5.

An enclosure designed for surface mounting that has swinging doors or covers secured directly to and telescoping with walls of the box

a)

Utility Box

b)

Cutout Box

c)

Junction Box

d)

Outlet Box

6.

Without live parts exposed to a person on the operating side of the equipment

a)

Safety Parts

b)

Dead Front

c)

Disconnected Front

d)

Dead Parts

7.

Intermittent operation in which the load conditions are regularly recurrent

a)

Duty, Periodic

b)

Duty, Intermittent

c)

Duty, Varying

d)

Duty, Short-Time

8.

The case or housing of apparatus, or the fence or walls surrounding an installation to prevent personnel from accidentally energized parts to protect the equipment from physical damage

(a)  

9.

Operation at a substantially constant load for an indefinitely long time.

a)

Duty Varying

b)

Duty, Periodic

c)

Duty, Continuous

d)

Duty, intermittent

10.

Operation for alternate intervals of (1) load and no load; or (2) load and rest; or (3) load, no load, and rest

a)

Duty, Continuous

b)

Duty, Periodic

c)

Duty, Intermittent

d)

Duty, Varying

11.

Surrounded by a case, housing, fence, or wall(s) that prevents persons from accidentally contacting energized parts

a)

Enclosed

b)

Enclosure

c)

Insulated

d)

Insulation

12.

Operation at loads, and for intervals of time, may be subject to wide variation.

a)

Duty, Short-Time

b)

Duty, Periodic

c)

Duty, Intermittent

d)

Duty, Varying

13.

An accessory such as lock nut, bushing, or other part of a wiring system that is intended primarily to perform a mechanical function rather than an electrical function

(a)  

14.

(a)   Any shaft-way, hatchway, well hole, or other vertical opening or space in which an elevator or dumb-water is designed to operate

15.

Conductor or conductive part intended to be energized

(a)  

16.

The highest current at rated voltage that a device is intended to interrupt under standard test condition

a)

Rated Current

b)

Over load Current

c)

Interrupting Rating

d)

Amperage

17.

Any current in excess of the rated current of equipment or the ampacity of a conductor. It may result from overload, short circuit, or ground fault

a)

Ground current

b)

Rated current

c)

Ampere rating

d)

Overcurrent

18.

Operation of equipment in excess of normal, full-load rating, or of a conductor in excess rated ampacity that when it persist for a sufficient length of time, would cause damage or dangerous overheating.

a)

Overload

b)

Overcurrent

c)

Over-voltage

d)

Underload

19.

Constructed or protected so that exposure to a beating rain will not result in the entrance of water under specified test conditions.

a)

Corrugated-Zinc

b)

Raintight

c)

Rainproof

d)

Roof-guard

20.

Constructed, protected, or treated so as to prevent rain from interfering with the successful operation of the apparatus under specified test conditions.

a)

Roof-Guard

b)

Safeguard

c)

Raintight

d)

Rainproof

21.

A (a)   is a contact device installed at the outlet for the connection of an attachment plug.

22.

The conductors and equipment for delivering electric energy from the serving utility to the wiring system of the premises served

a)

Service

b)

Service Cable

c)

Service Conductors

d)

Service Drop

23.

Service conductors made up in the form of a cable

a)

Service

b)

Service Cable

c)

Service Conductors

d)

Service Drop

24.

The conductors from the service point to the service disconnecting means

a)

Service

b)

Service Conductors

c)

Service Cable

d)

Service Drop

25.

The overhead service conductors from the last pole or other aerial support to and including the splices, if any, connecting to the service-entrance conductors at the building or other structure.

a)

Service

b)

Service Cable

c)

Service Conductors

d)

Service Drop

26.

An automatic or non-automatic device for transferring one or more load conductor connections from one power source to another

a)

Switch

b)

Switchboard

c)

Panelboard

d)

Breaker

27.

(a)   an automatic or non-automatic device for transferring one or more load conductor connections from one power source to another

28.

A large single panel, frame, or assembly of panels on which are mounted on the face, back, of both, switches, overcurrent and other protective devices,buses, and usually instruments.

a)

Switchboard

b)

Switch

c)

Panelboard

d)

Breaker

29.

A single panel or group of panel units designed for assembly in the form of a single panel, including buses and automatic overcurrent devices, and equipped with or without switches for the control of light, heat, or power circuits.

a)

Switchboard

b)

Switch

c)

Panelboard

d)

Breaker

30.

A compartment or chamber to which one or more air ducts are connected and that forms part of the air distribution system

a)

Plenum

b)

Ducting

c)

Airtight

d)

Raceway

31.

An enclosed assembly that may include receptacles, circuit breakers, fuse holders, fused switches, buses, and watt-hour meter mounting means.

a)

Power outlet

b)

Junction Box

c)

Utility Box

d)

Outlet Box

32.

An enclosed channel of metal or nonmetallic materials designed expressly for holding wires, cables, or busbars, with additional functions as permitted in this Code

a)

Metal Enclosure

b)

Racebars

c)

Raceway

d)

Metal Bars

33.

The point of connection between the facilities of the serving utility and the premises wiring

a)

Access point

b)

Connection Point

c)

Service Point

d)

Center Point

34.

Any electric circuit that energizes signaling equipment

a)

Signaling Circuit

b)

Signaling Equipment

c)

Equipment Circuit

d)

Equipment signal

35.

Any window used or designed to be used for the display of goods or advertising material whether is is fully or partly enclosed or entirely open at the rear and whether or not it has a platform raised higher than street floor level

a)

Platform Window

b)

Display Window

c)

Window View

d)

Show Window

36.

A protective device for assembly as an integral part of a motor or motor-compressor that, when properly applied, protects the motor against dangerous overheating due to overload and failure start.

a)

Temperature Switch (as applied to motor)

b)

Thermal Switch (as applied to motor)

c)

Thermal Protector (as applied to motor)

d)

Pressure Protector (as applied to motor)

37.

An electrically conductive path from the point of a ground fault on a wiring system through normally-current carrying conductors, equipment, or the earth to the electrical supply source

a)

Grounding Fault Path

b)

Electrode - Current Path

c)

Ground-Fault Current Path

d)

Fault Ground System

38.

A protective device for limiting surge voltages by discharging or bypassing surge current, and it also prevents continued flow of follow current while remaining capable of repeating these functions.

a)

Arrester

b)

Lightning Conductor

c)

Surge Arrester

d)

Limiting Surge Current

39.

A protective device for limiting transient voltages by diverting or limiting surge current.

a)

TVSS

b)

TVSV

c)

TVAA

d)

TVSA

40.

A complete system of air terminals, conductors, ground terminals, interconnecting conductors, arresters, and other connectors or fittings required to complete the system

a)

Terminal Lighting Protection System

b)

Lighting Protection System

c)

Air Protection System

d)

Ground Protection System