Font size
WorksheetsBE Quiz 3
Total questions: 30
Worksheet time: 16mins
Which are not included in the seven (7) power abnormalities?
Under Voltage
Over Voltage
Voltage Sap
Voltage Swell
Harmonics
Standard for Emergency and Standby Power systems
NFPA 20
NFPA 70E
NFPA 70
NFPA 110
Required to ensure the equipment rating are adequate to withstand the available short circuit energy available each point in electrical system.
Arc Flash Analysis
Load Flow Analysis
Coordination Study
Short Circuit Analysis
Electrical or electronic switch that is typically operated by using electromagnetism to operate a mechanical switch.
Frequency Delay
Power Factor Relay
Undervoltage Relay
Instantaneous Overcurrent Relay
None of the above
___________ is the ratio of the sum of the individual maximum demand of the various subdivisions of a system to the maximum demand of the whole system under consideration.
Diversity Factor
Demand Factor
Diversity System
Demand System
Dissipate fault-current by giving current many paths to travel into earth.
Bonding jumper
Grounded Conductor
Grounding Electrode
Equipment Ground Conductor
The maximum deviation from the average of the three phase voltages divided by the average of the three phases voltages value.
Harmonics
Transients
Under voltage
Over voltage
Voltage unbalance
A large assembly of panels, mounted on face, back or both, switches, overcurrent protective devices, buses and instruments. Accessible from rear and front.
Motor Control Centers
Switchgear
Panelboard
Transformer
Switchboard
What is the code required by "Standard for Electrical Practice on Workplace"?
NFPA 70E
NFPA 110
NFPA 72
NFPA 70B
For effects of Effects of Electrical Current on Human Body, the effect of Current (AC) - 20 mA is Paralysis of respiratory muscle
True
False
The type of testing which done by running the fire pump but the only water passing through the pump is a small flow that is discharged through the pump circulation relief valve or supplies the cooling for a diesel engine driver.
Back-to-tank Test
Churn Test
Load Test
It is an electrical device that converts direct current to alternating current.
Rectifier
Inverter
Transducer
It is to dissipate fault-current by giving current many paths to travel into earth.
Grounded conductor
Grounding electrode
Bonding jumper
Grounding electrode conductor
What is the Operating Lifespan of Liquid Filled Transformer?
15-25 years
25-35 years
20-30 years
10-20 years
Which of the following is the cause of over voltage?
Dropping of loads
Power shutdown
Malfunction of electronic devices
Actuation of over voltage relay
The protective devices are selectively
adjusted to minimize the impact of equipment failure within a system.
Coordination Study Analysis
Short Circuit Analysis
Arc Flash Analysis
Design Analysis
What is the code requirement of NFPA 101?
Life safety code
Fire code
National Fire Alarm Code
Building Construction and Safety
It is step-down Transformer which reduces the voltage of a high voltage circuit to a lower level for the purpose of measurement.
Potential Transformer
Current Transformer
Power Transformer
Circuit Breaker
(a) is/are an electrical device consisting of two or more coils of wire used to transfer electrical energy by means of changing magnetic field.
It is a ground mounted electric power distribution transformer in a locked steel cabinet mounted on a concrete pad. Since all energized connection points are securely enclosed in a grounded metal housing, a pad mount transformer can be installed in places that do not have room for a fenced enclosure.
Dry Type Transformer
Liquid Type Transformer
Which of the gas is not known as greenhouse gas?
Hydrogen
Nitrous Oxide
Carbon Dioxide
Methane
This is a type of Heat Transfer from fluid to fluid
Convection
Conduction
Radiation
This law states that energy can neither be created nor destroyed; energy can only be transferred or changed from one form to another.
Zeroth law of thermodynamics
First law of thermodynamics
Second law of thermodynamics
Third law of thermodynamics
In basic space comfort cooling, when heat is removed from an object and its temperature falls, the heat removed is also called _______.
Latent Heat
Conductive Heat
Sensible Heat
None of the above
Galvanized iron sheets have a coating of
Zinc
Lead
Chromium
Tin
In order to measure STATIC PRESSURE of the duct to ensure well distributed air, building engineer can perform or use ________.
Pitot tube
Balometer
Air Volume Meter
Air is a/an
Mixture
Element
Compound
Electrolyte
Hydraulic pressure in a tank is mainly dependent or directly proportional to the ________ of the liquid.
Weight of the liquid
Height of the liquid
Volume of the tank
none of the above.
A force that tends to produce an elongation of a body or structure.
Tension
Compression
Bending
Torsion
The ___________________ states that if two systems are in thermodynamic equilibrium with a third system, the two original systems are in thermal equilibrium with each other.
Zeroth Law of Thermodynamics
First Law of Thermodynamics
Second Law of Thermodynamics
Third Law of Thermodynamics
