EE8702_PSOC_Model_IV_Part B

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

The maximum demand of a consumer is 5 kW and his/her daily energy consumption is 24 units. His/her % load factor is

a)

5

b)

20

c)

25

d)

48

2.

A generating station has a connected load of 40 MW and a

maximum demand of 20 MW. The demand factor is

a)

0.7

b)

0.6

c)

0.5

d)

0.4

3.

If the load on an isolated generator is increased without

increasing the power input to the prime mover

a)

The generator will slow down

b)

The generator will speed up

c)

The generator voltage will increase

d)

The generator field

4.

Two alternators A and B are operating in parallel. If excitation of A is increased.

a)

reactive power of A is increased while that of B is decreased

b)

reactive power of A is increased while that of B is remain unchanged

c)

reactive power of A is decreased

d)

both real and reactive power of A are increased

5.

The units for speed regulation of governor are

a)

Hz

b)

Hz per MVA

c)

Hz per MW

d)

none of the choices

6.

The maximum demand on a power station is 100 MW. If the annual load factor is 40 %. Calculate the total energy generated in a year

a)

350×106350\times10^6 Units

b)

350 kWhr

c)

350×103350\times10^3 kWhr

d)

350\times10^6 MWhr

7.

Decentralized control system is used for larger power system because

a)

Centralized system is not possible

b)

Centralized control is more inefficient than decentralized control

c)

Modern LFC algorithm is difficult to implement in centralized manner

d)

All of above

8.

The equation of area control error(ACE) is

a)

ACE = ΔPtie + b.Δf

b)

ACE = ΔPtie - b.Δf

c)

ACE = ΔPtie +1/ b.Δf

d)

ACE = ΔPtie - 1/b.Δf

9.

Incremental cost of two generators Ic1 = 0.2 P1+60, Ic2 = 0.3 P2+40 and the ratings of the generator are 150 and 250 MW. Find the load sharing of each generator for a load of 200 MW?

a)

P1 = 120 MW, P2 = 80 MW

b)

P1 = 80 MW, P2 = 120 MW

c)

P1 = 100 MW, P2 = 100 MW

d)

P1 = 60 MW, P2 = 140 MW

10.

Which of the following methods is/are used for reactive or voltage compensation

a)

Shunt capacitor

b)

Series capacitor

c)

Generation excitation control

d)

All of the above

11.

Line compensation improve power system operation by

a)

Keeping voltage closer to nominal value

b)

Reduces line current and losses

c)

Enhance stability

d)

All of above

12.

Which of the following is/are the base load plants?

a)

Thermal plants

b)

Nuclear plant

c)

Hydro plant

d)

All of the above

13.

If the loading of the line corresponds to the surge impedance the voltage at the receiving end is

a)

Greater than sending end

b)

Less than sending end

c)

Equal to the sending end

d)

None of the above is necessary.

14.

If the penalty factor of a plant is unity, its incremental transmission loss is

a)

1.0

b)

– 1.0

c)

Zero

d)

None of the above

15.

The loss coefficients for a two-bus system are

a)

B11= 0.02, B22 = 0.05, B12= 0.01, B21 = 0.015

b)

B11= 0.02, B22 = 0.04, B12= -0.01, B21 = 0.01

c)

B11= 0.03, B22 = 0.005, B12= 0.001, B21 = -0.001

d)

B11= 0.03, B22 = 0.05, B12= 0.001, B21 = -0.001