WorksheetsCEA Loads, Beams, and Foundations
Total questions: 14
Worksheet time: 37mins
What foundation type is this image an example of?
Continuous (Strip) Footing
Cast-in-Situ Piles
Spread (Column) Footing
Mat Foundation
What foundation type is this image an example of?
Continuous (Strip) Footing
Cast-in-Situ Piles
Spread (Column) Footing
Mat Foundation
If the building pictured has a total design load of 73 psf then what would the exterior beam loading be?
1200
79
438
219
If the building pictured has a total design load of 73 psf then what would the interior beam loading be?
1200
79
438
219
Given a building with a dead load of 64 psf, live load of 0 psf, snow load of 10 psf, and roof live load of 30 psf. What would the total design load be?
104
94
74
40
What is the type of beam with one end pinned and the other end is a roller?
Cantilever Beam
Simply Supported beam
Fixed beam
Continuous Beam
What type of beam is shown here?
simply supported
cantilever
continuous
overhang
What type of beam is shown here?
simply supported
cantilever
continuous
overhang
What type of beam is shown here?
simply supported
cantilever
continuous
overhang
Which type of beam load is shown and what is the maximum shear force?
The beam is loaded with a uniform load, and the maximum shear force is (100 lbs/ft)(16 ft)/2 = 800 lb.
The beam is loaded with a uniform load, and the maximum shear force is (100 lbs/ft)(16 ft) = 1600 lb.
The beam is loaded with a concentrated load, and the maximum shear force is (1600 lbs/ft)/(8 ft) = 200 lb.
The beam is loaded with a concentrated load, and the maximum shear force is (1/2)(100 lb/ft)(8 ft) = 400 lb.
What is the reaction force at point B of the 20 ft steel beam, represented by the beam diagram, if w1 = 1200 lb/ft?
600
1200
12000
24000
What is the Moment Max of the 15 ft steel beam, represented by the beam diagram, if P = 800 lb?
3000
12000
400
800
A low rise commercial building is to be built on a site where the footing will rest on a clayey gravel. Each column will carry a load of 27,000 lb. A table of soil bearing capacities is shown.
Given that each concrete footing is 1’-6” thick, what are the plan dimensions for the most economical square spread footing to safely support each column load (up to the next 1 inch)?
3’-0” x 3’-0”
3’-2” x 3’-2”
3’-8” x 3’-8”
4’-8” x 4’-8”
A column carries a load of 35 kips and is supported on a 2-foot thick spread footing, which rests on silt. Size the smallest round footing (up to the next 3 inches) that can support the load.
3’3"
6'3"
29'3"
58'6"