WorksheetsBUILDING UTILITIES 1 - FINAL EXAMINATION
Total questions: 25
Worksheet time: 22mins
__________________ are used within fire detection systems in order to identify a developing fire emergency before it starts to create significant damage.
Fire Fighting System
Fire/Smoke Alarm System
Automatic Springkler System
Fire/Smoke Detectors
an engineered group of units that are built to extinguish fires through the application of a substance. The objective is to extinguish a fire as quickly as possible.
Fire Alarm System
Fire Detection System
Fire Fighting System
Fire Suppression System
A fire suppression systems that is environmentally friendly, the use of chemical reagents to extinguish fires in sensitive spaces like data centers full of computers and technology equipment.
Carbon Dioxide Suppression System
FM-200 Clean Agent
Wet Type Fire Suppression System
Dry Type Fire Suppression System
A Components of a Fire Suppression System that acts as the brain of the entire system and monitors every connected device and relays information between each part.
Initiating Device
Notification Appliances
Power Supply
Fire Alarm Panel
Automatic fire-fighting systems are installed in buildings and rooms where the fire hazard is comparatively Low.
True
False
a water reticulation system used to transport water in order to limit the amount of hose that firefighters have to lay, thus speeding up the fire fighting process.
Wet Standpipe System
Dry Standpipe System
Fire Hydrant System
Automatic Sprinkler System
a network of piping, water supply, heads, and alarm and detection devices that automatically detect the heat from a fire and automatically distribute water to completely put out or combat the fire or control its growth.
Automatic Fire Alarm System
AutomaticHeat Detector System
Automatic Fire Suppresson System
Automatic Springkler System
a newly formulated code that will abide to the ccelerating economic and physical development of urbanization and its technological advancements. This presidential decree embodies an improvement on the standards of
building design, construction, use, occupancy, and maintenance.
The Plumbing Code ot the Philippines
The Fire Code of the Philippines
The National Building Code of the Philippines
All of the Above
are areas within which only certain types of buildings are permitted to be constructed based on their use or
occupancy, type of construction, and resistance to fire.
Danger Zones
Industrial Zones
Fire Zones
Fire Safety Zones
the length of time a material can withstand being burned which may be one-hour, two-hours, three-hours,four-hours, etc.
Fire Resistive Standards
Fire Resistance Rating
Fire Resistive Rating Period
Fire Resistive Time Period Rating
Bottom of the pipe trenches deeper than the footing of any adjacent building structures and at least ______ degrees parallel.
30 degrees
20 degrees
45 degrees
60 degrees
Building sewers and other drainage pipings, constructed of materials approved for use under or within the building, shall NOT be installed under or within______ meters of any building or structure nor less than _______ meters below the finish ground surface.
0.30 meters & 0.60 meters
0.30 meters & 0.40 meters
0.60 meters & 0.40 meters
0.60 meters & 0.30 meters
Water closet or bidet should not be placed ________ meters from its center to any side wall.
0.375 meters
0.35 meters
0.20 meters
0.10 meters
No vent pipe will be used as a soil or waste pipe. No soil or waste pipe be used as a vent.
True
False
Gravity tanks shall be controlled by a _____________ or the like to prevent tank from overflowing.
Check Valve
Gate Valve
Float Valve
Pressure Valve
A ___________ allows users to have a place that is convenient to access a building’s drain pipes to clear any kind of debris.
Manhole
Service Hole
Cleanout
Vent Pipe
a fitting designed to provide a liquid seal which prevents backflow of foul air or methane gas without affecting the flow of sewage or wastewater.
Backflow Seal
Air Seal
Trap
Water Seal
A trap cannot serve more than _______ single compartment sinks or tubs for the reason that it might not be able to flow freely, this may disrupt the water flow.
1
2
3
4
The bottom of the water pipe should always be at least __________ above the top of the sewer or drain line.
.2m
.3m
.4m
.5m
Building sewers should have a uniform slope of ________% of the disposal point. The building sewer piping should be laid on a firm bed throughout its entire length.
2%
3%
4%
5%
A __________ test should be carried out for the connections and joints in the pipelines of the plumbing system.
Smoke Test
Air Test
Pressure Test
Vacuum Test
Minimum headroom shall not be less than __________ meters in accordance with the Fire Code of the Philippines.
2.00 meters
2.10 meters
2.70 meters
3.00 meters
Protective Enclosure of Exit. Separation shall have at least ________ hour fire resistance rating when the exit connects three (3) storeys or less
1 hour
1.5 hour
0.5 hour
0.3 hour
Exterior Ways of Exit Access. Arranged so that there are no dead-ends in excess of __________ meters in length.
4 meters
5 meters
6 meters
3 meters
System of vertical pipes in a building to which fire hoses can be attached on each floor, including a system by which water is made available to water outlets as needed
plumbing System
Fire Hose Rack System
Siamese Connector
Standpipe