wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Sanitary engineering

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

The trap which is not used in house drainage system is

a)

Gully trap

b)

P trap

c)

S trap

d)

C trap

2.

Growth of algae is useful in

a)

Sedimentation tank

b)

Slow sand filter

c)

Oxidation pond

d)

Sludge digestion tank

3.

Most significant gaseous air pollutant is

a)

Carbon dioxide

b)

Oxygen

c)

Nitrogen

d)

Sulphur dioxide

4.

Pipe which carries discharges from sanitary fittings such as water closets urinals etc called

a)

Waste pipe

b)

Vent pipe

c)

Discharge pipe

d)

Soil pipe

5.

A septic tank is a

a)

Sedimentation tank

b)

Digestion tank

c)

Combined sedimentation & digestion tank

d)

Aeration tank

6.

In the last man hole of house drainage system. The trap provided

a)

Gully trap

b)

S trap

c)

Floor trap

d)

Intercepting trap

7.

The term which is measured as vertical distance between crown and dip of trap

a)

Crest width

b)

Water seal

c)

Dip depth

d)

Depth of water

8.

The sewer appurtenance constructed to provide a connection between the high level branch sewer to low level main sewer

a)

Catch basin

b)

Man hole

c)

Drop manhole

d)

Deep man hole

9.

The system of carrying sewage through sewer

a)

Dry system

b)

Conservancy system

c)

Partially seperate system

d)

Sewerage

10.

Method of cleaning rapid sand filter

a)

Long laborious method

b)

CoMpressed air method

c)

Scraping

d)

Agitation and back washing

11.

The minimum velocity which will prevent the singing of particles in sewers

a)

Non scouring velocity

b)

Self cleansing velocity

c)

Scouring velocity

d)

None

12.

Which of the following equipment can be used for removal of paper and rags from sewers

a)

Claws

b)

Gauge

c)

Scraper

d)

Scoop

13.

All traps have a

a)

Filter

b)

Grating

c)

Water seal

d)

Gate valve

14.

Stall type urinals are best suited for

a)

High schools

b)

Residential houses

c)

People of same height

d)

Public places

15.

Minimum dia of manhole is

a)

200cm

b)

150cm

c)

100cm

d)

50cm

16.

Drive sludge is good

a)

Fuel

b)

Manure

c)

Filler of low lying area

d)

Soil builder

17.

Mostly adopted detonation period for septic tank under indian condition is

a)

12 hrs

b)

24 hrs

c)

48 hrs

d)

72 hrs

18.

A natural method of disposal of sewage is

a)

Sewage irrigation

b)

Septic tank treatment

c)

Composting

d)

Aereated lagooning

19.

Circular section of sewer is very common but it's best suited when dia is up to

a)

0.75m

b)

1.25m

c)

1.50m

d)

3m

20.

Bacteria die at temperature is more than

a)

50℃

b)

40℃

c)

30℃

d)

25℃