wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Masimo New Hire Training 2nd Day

Total questions: 15

Worksheet time: 15mins

Name
Class
Date
1.

Choose the incorrect statement about PVI

a)

PVI is a tool for functional assessment of fluid responsiveness

b)

PVI is calculated from PI changes during respiratory cycle

c)

PVI is accurate in spontaneous breathers

d)

PVI is one of the dynamic variables for fluid responsiveness assessment

e)

PVI cutoff value is 14

2.

Please choose the correct statements about CO

a)

Incomplete combustion of carbon based materials will produce CO

b)

Hemoglobin molecule has affinity to CO 200x to O2

c)

SpCO accuracy is 1%

d)

Hyperbaric chamber is the main line of treatment of CO poisoning

e)

Pulse oximeter will read 80% SpO2 for CO posoning

3.

SpCO accuracy is

a)

1%

b)

2%

c)

3%

d)

1.5%

4.

Choose the causes of methemoglobinemia from the following (multiple answers apply)

a)

Nitrous oxide

b)

EMLA cream

c)

Lidocaine

d)

Burn

e)

Bleeding

5.

SpMet accuracy is

a)

1%

b)

2%

c)

3%

d)

1.5%

6.

Choose the incorrect statement

a)

Methemoglobin level in normal people is 0-2%

b)

Methylene blue used for treatment of methemoglobinemia

c)

Pulse oximetry reads 95% in cases of methemoglobinemia

d)

NO causes methemoglobinemia in neonates

7.

ORI reflects

a)

SpO2 from 100-200

b)

PaO2 from 100-200

c)

SpO2 from 97%-100%

d)

PaO2 from 200-400

8.

Which of the following is a method of measuring respiratory rate

a)

RRa

b)

RRp

c)

Inspection

d)

ECG

e)

All of the above

9.

Awareness is

a)

Post operative recall of perception

b)

Recall of events

c)

Responsiveness

d)

Dreaming

e)

All of the above

10.

How do clinicians determine depth of anesthesia? choose all that apply

a)

MAC

b)

Capnography

c)

Blood pressure

d)

Temperature

e)

Heart rate

11.

Choose the most important competitive difference of Sedline

a)

Four active electrodes from both hemispheres

b)

DSA

c)

PSi

d)

Quantitative EEG

12.

We can see burst suppression on the following:

a)

EEG

b)

SR

c)

DSA

d)

PSI

e)

All of the above

13.

Propofol cause appearance of the following waves

a)

Delta and Theta

b)

Delta and Alpha

c)

Delta and Beta

d)

Beta and Gamma

14.

O3 accuracy in pediatrics

a)

3% trend accuracy and 5% absolute accuracy

b)

5% trend accuracy and 3% absolute accuracy

c)

3% trend accuracy and 4% absolute accuracy

d)

4% trend accuracy and 3% absolute accuracy

15.

Benefits of O3 Regional Oximetry

a)

Robust trending and absolute accuracy specifications

b)

Flexible as both trending and absolute monitors

c)

Flexible measurement expansion to include Masimo rainbow® SET®, SedLine and Capnography parameters

d)

High-resolution touchscreen display

e)

All of the above