NEW
Font size
WorksheetsManaging Abnormal Operation Condition
Total questions: 15
Worksheet time: 8mins
Suatu fasilitas beroperasi diluar Safe Operating Limit (SOL), hal ini berhubungan dengan aspek:
Design & Construction
Program & Prosedur
Human
Semua jawaban benar
Setting point PSV
Di atas SOL (Safe Operating Limit)
Di bawah SOL (Safe Operating Limit)
Dalam rentang SOL (Safe Operating Limit)
Dalam rentang NOL (Normal Operating Limit)
Manakah proteksi yang menjaga operasi berada dalam kondisi normal (NOL):
Control system
Shutdown system
Pressure relief system
Blowdown system
Insiden Process Safety dapat mengakibatkan
Kecelakaan kerja dan/atau kematian
Dampak lingkungan
Pengaruh buruk bagi reputasi perusahaan
Semua jawaban benar
Manajemenn resiko dari suatu abnormal operasi yang berhubungan dengan SCE dilakukan dengan:
HAZOP
SCEARA
HAZID
Risk Register
Apa kepanjangan dari SCEARA
Safety Critical Element Abnormal Risk Assessment
Safety Critical Evaluation & Risk Assessment
Safety Critical Element Analysis & Risk Assessment
Safety Critical Element Deviation Risk Assessment
Salah satu tahapan dalam SCEARA adalah melakukan Initiation meeting yang difasilitasi oleh
Process Safety Coach
Operation Manager
TA Discipline
General Manager (GM)
Apakah penipisan pipa gas di suatu fasilitas produksi merupakan process safety issue
Ya
Tidak
Mungkin
Tidak tahu
Berikut merupakan sumber abnormal operasi yang memerlukan SCEARA, kecuali
IAAN kategori B dan C
BIFO (Bypass, Inhibit, Force, Override) lebih dari 24 jam
Kerusakan SCE (SCE Impairment)
Penundaan SCE PM (SCE PM Deferral)
Berikut merupakan kondisi IAAN kategori A, kecuali
Kebocoran flammable materil
Penipisan dengan zero remaining live
Penipisan dengan remaining live di bawah 1 tahun tapi diatas nol tahun
Kebocoran toxic material
Safe Operating Limit (Zone) is the range between
Alarm Low Level to Alarm High Level
Trip Low Level to Trip High Level
Alarm High Level to Trip High Level
Zero to a point when the relief valve is open
Gas Blow By from a scrubber or separator is an undesired event because
Liquid fluid can carry over to the top and damaging the compressor
The liquid system downstream of scrubber bottom product of scrubber downstream exposed to a higher pressure exceeding its rating and potential for loss of primary containment
The scrubbers exposed to a higher pressure exceeding its rating and potential for loss of primary containment
The scrubber and pipe system experiencing shock chilling
Trouble Shooting Zone atau Operator Respond untuk mengembalikan proses ke normal berlaku ketika
Parameter proses (tekanan, level, temperature) berada di antara NOL dan SOL
Parameter proses berada ketika mendekati proses alarm
Ketika tangki dalam keadaan luber atau bocor
Ketika parameter proses alarm berbunyi dan operator harus berusaha agar proses kembali ke normal walaupun parameter proses telah melebihi SOL
Proses dikatakan berada dalam kondisi tidak normal ketika
Tangki telah melewati batas SOL
Tangki telah mengalami kebocoran atau luber
Tangki level tangki berada di atas NOL dan/atau Alarm berbunyi
Ketika manual valve tidak dapat dioperasikan
Keadaan mana di bawah ini yang mengharuskan operator mematikan aliran:
I. Tekanan separator telah membunyikan alarm
II. Hanya ketika Tangki sudah mengalami kebocoran atau luber.
III. Level tangki telah melewati batas SOL.
IV. Ketika tidak ada lagi indicator parameter proses (tekanan, level, atau temperature) tidak beroperasi (blind operation).
I dan III
I, II, dan III
III
III dan IV