Deculator in Air and Stock

Total questions: 20

Worksheet time: 11mins

Name
Class
Date
1.

It removed the entrained air in the stock before it enters the headbox.

a)

Defoamer

b)

Deculator

c)

Defoamer and Deculator

d)

None of the Above

2.

To cause foam bubbles to coalesce to the point where they are large enough to float harmlessly to the water surface.

a)

Defoamer

b)

Deculator

c)

Defoamer and Deculator

d)

None of the Above

3.

Behaves as part of the water phase.

a)

Entrained Gas

b)

Dissolved Gas

c)

Air Bubbles

d)

None of the Above

4.

Process where stock enters the deculator through several nozzles.

a)

Impinging

b)

Boil

c)

Spraying

d)

Flushing

5.

Requires cold water to reduce the temperature of the vapor passing to the first stage vacuum pump.

a)

Cooling Media

b)

Cooling Tower

c)

Fresh Water

d)

Pre Condenser

6.

What is the minimum elevation of Deculator from Fan Pump.

a)

30 meters

b)

30 centimeters

c)

30 inches

d)

30 feet

7.

Measures the amount of entrained air by volume.

a)

Entrained Gas Analyzer

b)

Entrained Gas Test

c)

Deculator Efficiency

d)

All of the above

8.

Process where the stock is impinged against the roof of the deculator.

a)

Impinging

b)

Spraying

c)

Boil

d)

None of the Above

9.

Have sufficient buoyancy to rise to the surface.

a)

Entrained Air

b)

Dissolved Air

c)

Air Bubbles

d)

Soft Drinks

10.

When pressure is reduce, dissolve gases can come out of the solution to form tiny bubbles that move along with the fiber.

a)

Entrained Air

b)

Dissolved Air

c)

Air Bubbles

d)

All of the Above

11.

Process at Deculator where Stock is introduced to a vessel under vacuum.

a)

Impinging

b)

Spraying

c)

Boil

d)

Flushing

12.

Formula for computing Deculator efficiency.

a)

= (Vol. entrain air out - Vol. entrain air in) / Volume of entrain air in

b)

= (Vol. entrain air in - Vol. entrain air out) / Volume of entrain air out

c)

= (Vol. entrain air in - Vol. entrain air out) / Volume of entrain air in

d)

= (Vol. entrain air in + Vol. entrain air out) / Volume of entrain air in

13.

True or False: Dissolved gas behaves as part of the water phase

a)

True

b)

False

14.

True or False: Too much defoamer does not affects the performance of AKD, but can cause or worsen deposit problems.

a)

True

b)

False

15.

True or False: Cavitation and plugging means accumulated fiber on pump impellers.

a)

True

b)

False

16.

True or False: Cavitation in centrifugal pumps creating higher energy consumption.

a)

True

b)

False

17.

True or False: Deculator process requires high temperature at pre condenser.

a)

True

b)

False

18.

True or False: Accept of 1Ry Cleaners will go to Deculator to remove entrained air before going to Headbox Fan pump.

a)

True

b)

False

19.

True or False: The stock will boil (vapor pressure) at temperature of 49ºC and atleast 26.5 in Hg vacuum pressure.

a)

True

b)

False

20.

True or False: Function of Deculator is to remove entrained air in the white water before it enters the heabox.

a)

True

b)

False