NEW
Font size
WorksheetsReview unit 6 Part-2
Total questions: 63
Worksheet time: 16hrs 45mins
Refer to the figure Shown below. Where is the coil of timing relay connected?
TB2-1 and TB3-16
TB1-13 and TB1-14
TB2-16 and TB2-17
TB1-10 and TB1-11
Refer to the figure Shown below. Where is the coil of control relay 1 connected?
TB2-1 and TB3-16
TB1-13 and TB1-14
TB2-16 and TB2-17
TB1-10 and TB1-11
Refer to the figure Shown below. Where is the hold contact relay connected?
TB2-1 and TB3-16
TB2-14 and TB2-15
TB2-20 and TB2-21
TB1-10 and TB1-11
Refer to the figure Shown below. Where is the contact of timing relay connected?
TB2-1 and TB3-16
TB2-14 and TB2-15
TB2-20 and TB2-21
TB1-10 and TB1-11
Where is the solenoid 1 connected?
TB2-2 and TB3-19
TB2-1 and TB2-2
TB2-14 and TB2-15
TB2-16 and TB2-17
Refer to the figure Shown below. What is the device used to releasing and returning the relay to its original condition?
Hold circuit
Control relay
Latching mechanism
Timing relay
Refer to the figure Shown below. What will happen If PB ON is Pressed and released?
The solenoid will energize and remain energized
The solenoid will de-energized
The solenoid will energize and then de-energize
Unlatch relay will energize and remain energized
Refer to the figure Shown below. What will happen If PB OFF is pressed?
LR(L) latch coil & LR (U) energized and Solenoid de-energized
LR(L) latch coil and Solenoid energized
LR(u) unlatch coil energized and Solenoid de-energized
Nothing will happen
Refer to the figure Shown below. How to energize the solenoid?
When PB ON and OFF Pressed
When PB ON Pressed
When PB ON pressed and released
When PB OFF Pressed
Refer to the figure Shown below. How to de- energize the solenoid?
When PB ON and OFF Pressed
When PB ON Pressed
When PB ON pressed and released
When PB OFF Pressed
What type of relay often serves as a memory device in case of power failure?
Timing relay
Control relay
Overload
Latching relay
The latch mechanically holds the contacts when the latch coil is de-energized is___________
magnetic
Control relay
mechanism
Latching relay
How can the solenoid be de-energized after it has been energized?
Press PB1 and PB2 at the same time
Press PB2 (off ) only
Close LR contact manually
Press PB1 (on) only
What is the timer in the Agastat time delay relay, which works by adjusting the size of an opening to control the time needed for air to pass from one container to another?
Clock timer
Dashpot timer
Motor driven timer
Electronic timer
What is the timer are used when plant equipment has cycling (on-off) and set sequence of operation?
Clock timer
Dashpot timer
Motor driven timer
Electronic timer
What is the type of timer .which operates on direct current on plants they are generally replaced rather than repaired?
Clock timer
Dashpot timer
Motor driven timer
Electronic timer
What is the type of timer used in synchronous motor run at the line frequency?
Clock timer
Dashpot timer
Motor driven timer
Electronic timer
What is the type of timer which open or close circuit after a specified time?
Dashpot timer
Motor driven timer
Interval timer
Electronic timer
What is the type of timer used on an oven or clothes dryer operates in sync with the line frequency of the ac power source?
Clock timer
Dashpot timer
Motor driven timer
Electronic timer
What type of relay, which is mechanical held in position and no current flows through the operating coils after switching?
Timing relay
Latching relay
Motor driven timer Relay
Control relay
What type of circuit used to call attention to equipment failure or upset condition in a plant process which is either visual or audible?
Timing relay circuit
Control relay circuit
Overload circuit
Latching alarm circuit
What holds the latching relay contacts in position when the circuit is de-energized?
magnetic
Control relay
mechanism
Latching relay
What type of relay has a mechanism which mechanically holds the contact even if it's coil is de-energized?
Timing relay
Control relay
Overload
Latching relay
What type of control circuit provides low voltage / no voltage protection for 3-phase motors?
One wire control circuit
Two wire control circuit
Three wire control circuit
Four wire control circuit
What type of control circuit provides no low voltage I no voltage protection for 3-phase motors ?
One wire control circuit
Two wire control circuit
Three wire control circuit
Four wire control circuit
What is the special safety device which prevents two parts of the circuit from being energized at the same time?
Latching mechanism
Timing relay
Interlocking
Interval timer
What type of logic function where two or more switches connected in series with the load?
AND
OR
NOT
MEMORY
What type of logic function where two or more switches connected in parallel with the load?
AND
OR
NOT
MEMORY
What type of logic function where a normally closed push button is connected to a load?
AND
OR
NOT
MEMORY
What type of logic function where a circuit is able to keep the load energized after the control signal is removed?
AND
OR
NOT
MEMORY
What type of logic function to keep the load remains energized when there is no control signal?
AND
OR
NOT
MEMORY
Refer to the figure below, What type of logic function?
AND
OR
NOT
MEMORY
Refer to figure below, What type of logic function?
AND
OR
NOT
MEMORY
Refer to the figure below, What type of logic function?
AND
OR
NOT
MEMORY
Refer to the figure below, What type of logic function?
AND
OR
NOT
MEMORY
Refer to the figure below, What type of logic function?
AND
OR and NOT
NOT and MEMORY
MEMORY and NOT
Refer to the figure below, What type of logic function in Starting circuit?
AND
OR
NOT
MEMORY
Refer to the figure , What type of logic function in Stopping circuit?
AND
OR
NOT
MEMORY
Refer to figure below, What type of logic function AND ?
Refer to figure below, What type of logic function NOT ?
Refer to figure below, What type of logic function OR ?
Refer to figure below, What type of logic function MEMORY ?
Refer to figure below. Identify the problem in control circuit if the voltmeter reading (Zero V)?
Open circuit between L1 and Coil or L2 and Coil
Open circuit between test points 9 and 10 or no power
LI and L2 do not have power supply
Short circuit between L1 and L2
Refer to figure below. Identify the problem in control circuit if the voltmeter reading (Zero V)?
Open circuit between L1 and Coil or L2 and Coil
Open circuit between test points 9 and 10 or no power
LI and L2 NO have power supply
Short circuit between L1 and L2
Refer to figure below. Identify the problem in control circuit if the voltmeter reading (Zero V)?
Open circuit between L1 and Coil or L2 and Coil
Open circuit between test points 9 and 10 or no power
LI and L2 NO have power supply
Short circuit between L1 and L2
What will be the expected voltmeter reading at the test point shown in figure if the contact is good and no breaks on conductor ?
Zero Volt
55 Volts
110 Volts
220 Volts
Refer to figure below. The control circuit supply 220 V. When the push button , the voltage measured (Zero Volt)
The problem in the circuit causing the relay coil to fail to operate
The problem in the power supply cause the coil overheat and burn out
Any contacts closing
Any contacts are not closing(open)
Refer to figure below. If the resistance of the coil is 50Ω is operating correctly, but the Ohmmeter reading is less than 50 Ω . What does it tells you?
coil is Opened
Correct operating
coil is Shorted
All of above
Refer to figure below. If the resistance of the coil is 50Ω is operating correctly, but the Ohmmeter reading is Infinity Ω or ( OL ). What does it tells you?
Correct operating
coil is Shorted
coil is Opened
All of above
What is the Part of a manual 3-Phase starter; this operates the contact mechanism from a toggle switch or push button?
Latching mechanism
Mechanical Linkage
thermal & magnetic
Heater coil
What is the Part of a manual 3-Phase starter, it protects motors against continual high starting current and heavy overloads?
Latching mechanism
Mechanical Linkage
thermal & magnetic
Overload relay
How to reset manual starter, after its overload relay opens?
Start /reset button
Stop/ reset button
Start than stop
Stop than start
On a manual starter, when does the overload relay opens its contacts
When there is ground fault
When there is excessive current
When there is high voltage
When there is open circuit
The bimetallic strip in a snap action overload relay is formed into a_________________
Bends
Curved disc
Heater coil
Overload relay
Refer the figure below what type of thermal overload relay?
Bimetallic relay
Snap action
Melting alloy devices
Overload relay
The bimetallic strip in a snap action overload relay when temperature increases
the disc moves _________________
Bends
Curved disc
upward
downward
The bimetallic strip in a snap action overload relay what happen if used to make break large current needing fast overload response?
Bends
Curved disc
Move upward
Arc and burn
What happens to a bimetallic strip when it is heated?
Bends
Curved disc
Move upward
Arc and burn
What is the main part of melting alloy the heater of this overload relay is the?
Pawl
Ratchet wheel
Melting alloy tube
Heater coil
In the melting alloy overload relay there is a part called ratchet wheel pin, what is the other name for it?
Pawl
Ratchet wheel
Melting alloy tube
Heater coil
When excessive current passes through the heater coil it get hot of melting alloy overload relay causes heating the ____________________
Pawl
Ratchet wheel
outer tube
Heater coil
When excessive current passes through the heater coil it heating the outer tube and gets hot to ____________________ of melting alloy overload relay
Pawl
Ratchet wheel
outer tube
alloy melt
When excessive current passes through the heater coil it heating the outer tube and gets hot to alloy melts cause__________________________ of melting alloy overload relay
Heater is free to turn
Ratchet wheel is free to turn
outer tube is free to turn
tube is free to turn