wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

CE 35 BUILDING DESIGN QUIZ 1A

Total questions: 30

Worksheet time: 18mins

Name
Class
Date
1.

Under PD 1096, what is the minimum area in every storey, basement, or cellar used

for habitation, recreation, dining, study, or work wherein fire-extinguishing systems

are required? (NBC IRR Sec.1212)

a)

250 square meters   

b)

100 square meters   

c)

150 square meters

d)

200 square meters

2.

Which of the following minor constructions is NOT exempted from building permits?

(NBC IRR Sec.301 / NBC 006)

a)

Garden masonry walls other than party walls not exceeding 1.20 meters in height, footpaths,       residential garden walks and/or driveways

b)

Addition of open terraces or patios resting directly on ground, not exceeding 20 sq. m. in total floor area, exclusively for the private use of the owner

c)

Garden pools for the habitation of water plants and/or aquarium fish not exceeding 200 mm in      depth and exclusively for private use

d)

Installation of window grilles

3.

The following are the minimum requirements for Group A dwellings, except

a)

Every dwelling shall be provided with at least one sanitary toilet and adequate washing and drainage facilities

b)

Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least 250 millimeters thick and 600 millimeters below the surface of the ground

c)

Every dwelling shall be so constructed and arranged as to provide adequate light and ventilation

d)

There shall be at least two entrances and another one for exit

4.

What is the minimum clear width of the stairs for Group A dwellings?

a)

0.70m

b)

0.60m

c)

0.80 m

d)

0.75m

5.

Which of the following is the minimum ceiling heights measured from the floor to the ceiling for a habitable room provided with artificial ventilation?

a)

2.3m

b)

2.6m

c)

2.4m

d)

2.75m

6.

Which of the following statement is true about the minimum sizes and horizontal dimensions of rooms?

a)

The minimum area of rooms for human habitation is 6.50 sq.m with a least dimension of 2.00 meters

b)

The minimum area of Kitchen is 3.00 sq. meters with a least dimension of 1.50 meters

c)

The minimum area of Bath and toilet is 1.40 sq. meters with a least dimension of 900 millimeters.

d)

The minimum area of rooms for human habitation is 6.00 sq.m with a least dimension of 2.50 meters

7.

The total floor area of a room without an artificial ventilation system is 12.50 sq.m. Determine the total free area of the window/windows openings that must be provided?

a)

1.20 sq.m

b)

1.23 sq.m

c)

1.00 sq.m

d)

1.27 sq.m

8.

In locating window openings, it should be borne in mind that in cases of extreme emergencies windows must serve as emergency egress to vacate the premises or access for rescue operations. Such windows shall meet the following requirements, except

a)

They can be opened from the inside without the use of any tools

b)

Where storm shutters, screens or iron grilles are used, these shall be provided with quick opening mechanism so that they can be readily opened from the inside for emergency egress and shall be so designed that when opened they will drop to the ground

c)

The minimum clear opening shall have a width not less than 820 millimeters and a height of 1 meter

d)

The bottom of the opening should not be more than 820 millimeters from the floor

9.

Who shall be the responsible for carrying out the provision of the Building Code as well as the enforcement of orders?

a)

Building Officials

b)

Authority

c)

Office of the City Engineer

d)

DOH

10.

Every required exit doorway shall be of a size as to permit the installation of a door not less than 900 millimeters in width and not less than _____meters in height

a)

2.4meters

b)

2.2meters

c)

2.0meters

d)

2.1meters

11.

It is situated outside of private property, a public land that should be equally enjoyed by all members of the community

a)

Parking lot

b)

Easement

c)

Court

d)

egress

12.

Cut slopes for permanent excavations shall not be steeper than _____(NBC IRR Sec.1202)

a)

Two horizontal to One Vertical

b)

Three horizontal to One Vertical

c)

One horizontal to Two Vertical

d)

One horizontal to Three Vertical

13.

   It shall be installed at low points of the roof and shall be adequate in size to discharge all tributary waters.

a)

Fascia Board

b)

Flashing

c)

Roof Drains

d)

Vent

14.

Every building four or more storeys in height shall be equipped with one or more _____ . (NBCP IRR, sect. 1212)

a)

Oxygen Tank

b)

Fireplace Chimneys

c)

Dry Standpipes

d)

Fire Exit

15.

Conductors shall have a horizontal clearance of not les than _______ from windows, doors, porches, fire escapes, or similar locations.

a)

1 meter

b)

2 meters

c)

1.5 meters

d)

2.1 meters

16.

The effective temperature and relative humidity of the air to be used for comfortable cooling shall be maintained at _____________and 50% to 60%, respectively, with 4.60 to 7.60 meters per minute air movement within the living zone.

a)

25°Celsius to 30°Celsius

b)

17°Celsius to 21°Celsius

c)

20°Celsius to 24°Celsius

d)

22°Celsius to 28°Celsius

17.

What is the Minimum thickness for a Non-bearing wall? Table 411.3.1.1

a)

150mm

b)

200mm

c)

100mm

d)

    75mm

18.

For parallel non-prestressed reinforcement in a horizontal layer, clear spacing shall be ____ NSCP, sec 425.2.1

a)

At least the greatest of 50mm, db, (2/3)dagg

b)

At least the greatest of 100mm, db, (4/3)dagg

c)

At least the greatest of 50mm, 2db, (4/3)dagg

d)

At least the greatest of 50mm, db, (4/3)dagg

19.

For parallel non-prestressed reinforcement placed in two or more horizontal layers, reinforcement in the upper layers shall be placed directly above reinforcement in the bottom layer wit a clear spacing between layers of at least ______ NSCP, sec 425.2.2

a)

27mm

b)

   20mm

c)

25mm

d)

30mm

20.

According to NSCP Table 425.3.1, Standard Hook Geometry for Development of Deformed Bars in Tension, the length of the straight extension for a 90 -degree hook using 10mm dia. bar is?

a)

   6db

b)

  8db

c)

10db

d)

12db

21.

Horizontal drainage pipes shall be run in practical alignments and at a uniform slope between manholes of not less than ____________ toward the point of disposal

a)

20mm/m

b)

25mm/m

c)

27mm/m

d)

30mm/m

22.

Septic tanks shall have a minimum of _____ compartments

a)

  One

b)

  Two

c)

   Three

d)

Four

23.

For shallow foundations, the Overall depth of foundation shall be selected such that the effective depth of bottom reinforcement is at least ____________ (NSCP sec 413.3.1.2)

a)

100mm

b)

75mm

c)

175mm

d)

150mm

24.

Required to transmit forces from one component to another

(a)  

25.

A connection between two structural elements joint at their ends to form a single, longer element

(a)  

26.

A steel element/s embedded in concrete

(a)  

27.

It is a member subjected primarily to flexure and shear, with or without axial force or torsion

(a)  

28.

A member, usually vertical or predominantly vertical, used primarily to support axial compressive load, but that can also resist moment, shear, or torsion

(a)  

29.

What is the specified concrete cover for Cast-in-place non-prestressed concrete Beams not exposed to weather or in contact with ground? (NSCP table 420.6.1.3.1)

a)

75 mm

b)

50mm

c)

40mm

d)

20mm

30.

Under PD 1096, what is referred to as construction in an existing building or structure involving changes in materials used, partitioning, location, and size of openings, etc., but does not increase the overall area? (NBC IRR Sec.106)

a)

Repair

b)

Conversion

c)

Renovation

d)

Alteration