wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Review unit 4 part 4

Total questions: 52

Worksheet time: 13hrs 0mins

Name
Class
Date
1.

Which type of polarity is shown in the figure?

a)

Parallel

b)

Additive

c)

Series

d)

Subtractive

2.

According to the voltmeter reading. What type of polarity is shown in the figure?

a)

Series

b)

Subtractive

c)

Additive

d)

Parallel

3.

What test is being performed in the figure shown?

a)

polarity test

b)

short circuit test

c)

ground test

d)

open circuit test

4.

What test is being performed in the figure shown?

a)

polarity test

b)

short circuit test

c)

ground test

d)

open circuit test

5.

What test is being performed in the figure shown?

a)

polarity test

b)

short circuit test

c)

ground test

d)

open circuit test

6.

What is Continuity test on a transformer?

a)
b)
c)
d)
7.

What is Insulation test on a transformer?

a)
b)
c)
d)
8.

What is Ground test on a transformer?

a)
b)
c)
d)
9.

Which one of the following is an advantage of three-phase power over single-phase power?

a)

There will be interruption total power.

b)

It only supplies line-to-line single-phase voltage.

c)

It does not have constant level power and high cost

d)

It can service for both single and three-phase load.

10.

Which one of the following is an advantage of three-phase power over single-phase power?

a)


Smaller operating machines with better operating characteristics

b)

It only supplies line-to-line single-phase voltage.

c)

It does not have constant level power and high cost

d)

It can service for three-phase load.

11.

Which one of the following is an advantage of three-phase power over single-phase power?

a)

There will be interruption total power.

b)

It only supplies line-to-line single-phase voltage.

c)

It has 3-phase voltage and 3-line voltage.

d)

It can service for both single

12.

Which one of the following is an advantage of three-phase power over single-phase power?

a)

There will be interruption total power.

b)

It only supplies line-to-line single-phase voltage.

c)

It does not have constant level power and high cost

d)

It can supply six separate single phase voltage.

13.

Which one of the following is an advantage of three-phase power over single-phase power?

a)

There will be interruption total power.

b)

It only supplies line-to-line single-phase voltage.

c)

more constant level of power and lower cost

d)

more constant level of power and high cost

14.

What is The equation used to calculate the voltage in a balanced WYE connection?

a)

VL = 1.73xVph

b)

VL = Vph / 1.73

c)

VL = Vph

d)

VL = Vph x P.F

15.

What type of voltage is taken between any two phases?

a)

Phase voltage.

b)

Line voltage

c)

Three phase voltage.

d)

Dc voltage.

16.

What type of voltage are available from three phase generator?

a)

Line voltage and phase voltage

b)

Line current and phase current

c)

Three –phase voltage

d)

voltage and phase voltage and Three –phase voltage

17.

What is The equation used to calculate the current in a balanced Delta connection?

a)

IL = 1.73xVph

b)

IL = Iph / 1.73

c)

IL = 1.73xIph

d)

VL = Vph x P.F

18.

What type of voltage is taken between each phase and neutral?

a)

Phase voltage.

b)

Line voltage

c)

Three phase voltage.

d)

Dc voltage.

19.

In a balanced three phase system, the equation use to calculate total power can be found by:

a)

P = x VL x IL / PF

b)

P = 3 x V x I x sin Ø

c)

P = I x V

d)

P = VL x ILx P.F x 1.73

20.

The star connected source can supply power to_____________

a)

Two separate single -phase supply voltages

b)

Three separate single -phase supply voltages

c)

Five separate single -phase supply voltages

d)

Six separate single phase supply voltages

21.

Refer the figure shown. What type connection of three-phase generator the start of each winding is connected together?

a)

Delta connection

b)

Star(Wye) connection

c)

Delta/wye connection

d)

Parallel connection.

22.

121.

Refer the figure shown. What type connection of three-phase generator the start of a winding (1) is connected to finish of another winding (2)?

a)

Star(Wye) connection

b)

Delta/wye connection

c)

Parallel connection.

d)

Delta connection.

23.

What type of two single-phase voltage are available from three phase System?

a)

two Line voltage and two phase voltage

b)

Line current and phase current

c)

Three –phase voltage

d)

Phase Voltage and Line Voltage.

24.

Refer the figure shown. What type connection of three-phase generator?

a)

Wye connection 3-wire generator with single phase lighting load

b)

Wye connection 4-wire generator with single phase lighting load

c)

Delta connection 3-wire generator with single phase lighting load

d)

Delta connection 4-wire generator with single phase lighting load

25.

Refer the figure shown. What type connection of three-phase generator with motor?

a)

Wye connection of generator with Delta connection of motor

b)

Delta connection of generator with Delta connection of motor

c)

Wye connection of generator with wye connection of motor

d)

Delta connection of generator with Wye connection of motor

26.

Refer to the figure. Calculate the line voltage as shown

a)

120 V

b)

71 V

c)

208 V

d)

336 V

27.

Refer to the figure. Calculate the line Voltage and line Current if Phase current 10 A as shown

a)

240 V

b)

17.3 V

c)

13.7 A

d)

17.3 A

28.

Refer to the figure. Calculate the line Voltage as shown

a)

130 V

b)

71 V

c)

207.6 V

d)

225 V

29.

Refer to the figure. Calculate the line Voltage as shown

a)

120 V

b)

71 V

c)

207.6 V

d)

300 V

30.

Refer to the figure. Calculate the line Current and line voltage as shown

a)

35.5A& 36813 V

b)

35.5 A & 600 V

c)

20.5 A & 36813 v

d)

20.5 A & 600 V

31.

The line voltage in wye connected system is 755 volt .calculate the phase voltage

a)

540 v

b)

1100 v

c)

436 v

d)

755 v

32.

The line voltage in wye connected system is 480 volt .calculate the phase voltage

a)

540 v

b)

1100 v

c)

277 v

d)

755 v

33.

Calculate the three phase power for the circuit with P.F 0.75

, line Voltage is 240 V and line current 10 A

a)

3118 Watt.

b)

31209 Watt

c)

543212 Watt

d)

5114 Watt

34.

Which of the following figures shows the correct connection when measuring power using two-wattmeter method?

a)
b)
c)
d)
35.

Refer to figure .How the Current coils of the wattmeter connected

a)

In parallel between Phase A and B

b)

In opposite polarity

c)

In series to the A & B with phase line conductor

d)

Across the voltage coils

36.

Refer to figure .How the Voltage coils of the wattmeter # 1 connected

a)

In parallel between Phase A and C

b)

In opposite polarity

c)

In series to the A & C with phase line conductor

d)

Across the voltage coils

37.

Refer to figure .What is total measure power in three phase circuit?

a)

Pt = W1 /W2

b)

Pt= W1-W2

c)

Pt= W1+W2

d)

Pt= W1xW2

38.

What is the common term for a fault or abnormal excessive current caused by short-circuit?

a)

problem

b)

inrush current

c)

open circuit

d)

overload

39.

What are the two major concerns when designing and installing a switchgear?

a)

economical and durable

b)

safety and reliability

c)

rugged and simple

d)

non-dependable and robust

40.

Which device use in switchgear to allow the unit to operate safely and prevent you from touching or removing a CB while it is energized?

a)

overload device

b)

disconnect switch

c)

Interlocking

d)

safety switch

41.

What is called for switching unit that can handle large amounts of power, considerably larger than the basic circuit breakers?

a)

Switchgear

b)

Inrush current

c)

Circuit Breaker

d)

Overload

42.

What is the part of the switchgear CB’s that allows you to push the breaker into the compartment easily?

a)

Overload device

b)

Disconnect switch

c)

Interlocking

d)

Rollers

43.

What is used to lift and fit heavy and bulky CB’s into its compartment?

a)

Lifting adaptor

b)

Levers

c)

Forklift

d)

Manual

44.

What is the part of the switchgear CB’s that used to release the Interlocking devices?

a)

Levering device

b)

Inrush current

c)

Circuit Breaker

d)

Rollers

45.

Refer to figure 9 Switchgear Breaker unit parts. What is the Part # 3?

a)

Roller

b)

Sensors

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

46.

Refer to figure 9 Switchgear Breaker unit parts. What is the Part # 4 ?

a)

Roller

b)

Sensors

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

47.

Refer to figure 9 Switchgear Breaker unit parts. What is the Part # 7 ?

a)

Roller

b)

Sensors

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

48.

Refer to figure Switchgear Breaker unit parts. What is the Part # 8 ?

a)

Roller

b)

Sensors

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

49.

Refer to figure Switchgear Breaker unit parts. What is the Part # 2 ?

a)

Roller

b)

Arc chute

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

50.

Refer to figure Switchgear Breaker unit parts. What is the Part # 10?

a)

Roller

b)

Main Disconnecting Contacts

c)

Levering device arm remove position

d)

Secondary disconnecting contacts

51.

What are the reasons of using the metal clad assembly when producing the switchgear?

a)

For environmental protection

b)

Spark containment

c)

Personal protection

d)

All of this

52.

What is use of three-Phase Switch gear?

a)

Reduce Current

b)

Isolate High voltage

c)

Lifting adapter

d)

For environmental protection