NEW
Font size
WorksheetsPhilippine Electrical Code_Definitions_Part 1
Total questions: 25
Worksheet time: 24mins
The permanent joining of metallic parts to form an electrically conductive path which will assure electrical continuity and the capacity to conduct safely any current likely to be imposed.
Bus
Hoistway
Bonding
Wireway
A device designed to open and close a circuit by nonautomatic means and to open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating.
Circuit breaker
Switchboard
Switchgear
Fixture
All circuit conductors between the service equipment, or the generator switchboard of an isolate plant, and the final branch-circuit overcurrent device.
Wireway
Feeder
Service
Busway
Capable of being inadvertently touched or approached nearer than a safe by a person. It is applied to parts not suitably guarded, isolated, or insulated.
Exposed
Accessible
In sight from
Equipment
The sum of the continuous ratings of the load consuming apparatus connected to the system or any part thereof.
Maximum demand
Continuous load
Connected load
Ampacity
A load where the maximum current is expected to continue for three hours or more.
Connected load
Continuous load
Maximum demand
Appliance
The unit of luminous flux. It is equal to the flux through a unit solid angle (steradian) from a uniform point source of one candle, or to the flux on a unit surface all points of which are at unit distance from a uniform point source of one candle.
Candela
Lux
Illuminance
Lumen
Any shaft way, hatchway, well hole, or other vertical opening or space in which an elevator or dumbwaiter is designed to operate.
Service lateral
Raceway
Hoistway
Busway
Capable of being removed or exposed without damaging the building structure or finish, or not permanently closed in by the structure or finish of the building.
Concealed
Fitting
Accessible
Exposed
Utilization equipment, generally other than industrial, normally built in standardized sizes or types, which is installed or connected as a unit to perform one or more functions such as clothes washing, air conditioning, food mixing, deep frying, etc.
Intermittent duty
Load
Equipment
Appliance
Capable of being reached quickly for operation, renewal, or inspections, without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders, chairs, etc.
Readily Accessible
Exposed
In sight from
Switchboard
The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s).
Feeder
Branch circuit
Busway
Grounded circuit
So constructed that dust will not enter the enclosing case under specified test conditions.
Dustproof
Dusttight
Drip-proof
Concealed
So constructed or protected that dust will not interfere with its successful operation.
Concealed
Dusttight
Drip-proof
Dustproof
One or more rooms for the use of one or more persons as a housekeeping unit with space for eating, living and sleeping and permanent provisions for cooking and sanitation.
Service
Hoistway
Garage
Dwelling unit
A disruptive discharge around or over the surface of a solid or liquid insulator.
Flashover
Surge
Overcurrent
Overload
The highest current at rated voltage that an over current protective device intended to interrupt under standard test conditions.
Nominal voltage
Maximum demand
Interrupting rating
Overcurrent
_____ is the largest of all the demands which have occurred during the specified period of time.
Ampacity
Peak load
Demand factor
Maximum demand
Approved steel or metal troughing (usually with removable cover), and fitting therefore, so formed and constructed that insulated conductors may be readily drawn in and withdrawn, or laid in and removed, without injury either to conductor or covering.
Busway
Wireway
Raceway
Lateral conductor
A general term covering an assembly or assemblies of devices for the interruption, control, metering of electric power.
Switchgear
Switchboard
Circuit breaker
Service equipment
A large single panel, frame, or assembly of panels on which are mounted, on the face or back or both, switches, overcurrent and other protective devices, buses, and usually instruments.
Switchgear
Panel board
Switchboard
Service equipment
A sudden upward transient variation in the current, potential or power.
Overcurrent
Surge
Short circuit
Flashover
The _____ of a circuit of a system or circuit is a nominal value assigned to a system of a circuit of a given voltage class for the purpose of convenient designation.
maximum demand
connected load
nominal voltage
demand factor
The conductors and equipment for delivering energy from the electricity supply system to the wiring system of that premises served.
Service lateral
Service
Service drop
Service equipment
A conductor, a group of conductors, in switchgear assemblies which serves as a common connection for two or more circuits.
Lateral conductor
Branch circuit
Feeder
Bus