NEW
Font size
WorksheetsBUILDING UTILITES 2 FINAL EXAM
Total questions: 20
Worksheet time: 15mins
The rated speed Of Escalators shall be not more than 0.64 m/s except that higher speeds may be permitted subject to the approval of the enforcing authority.
0.61 m/s
0.62 m/s
0.63 m/s
0.64 m/s
An electric motor shall not drive more than _____ escalator.
one
two
three
four
A speed governor shall be provided in the escalator, the operation of which will cause the interruption of power to the driving machine should the speed of the steps exceed a pre-determined value, which shall be not more than ____% above the rated speed.
30%
40%
50%
60%
a type of vertical transport equipment that efficiently moves people or goods between floors (levels, decks) of a building, vessel or other structures.
Powered by Electric Motors
Escalator
Elevator
Conveyor
Chutes
Exclusively used for carrying materials and shall not carry any person.
Passenger
Lift
Goods
Lift
Service
Lift
Cargo
Lift
These lifts are self-contained and can be easily moved to where they are needed.
Hospital
Lift
Goods
Lift
Scissors
Lift
Service
Lift
The machine room and the escalator hoistway shall be finished with mortar or other materials so as to prevent concrete dust.
TRUE
FALSE
When the hospital elevator can be made accessible at any other level which is accessible by means of an elevator with a minimum width of ____ mm
600 mm
700mm
800 mm
900 mm
Most common type of elevator. Elevator cars are pulled by means of rolling steel ropes over a deeply grooved pulley also called sheave.
Electric
Elevator
Traction
Elevator
Gearless
Traction
elevator
Hydraulic
Elevator
Escalator Inspection are required once a year.
TRUE
FALSE
Every occupant of a high-rise commercial building needs to take lifts at least _____ times a day, in the morning, during lunch and after office hours
THREE
FOUR
FIVE
TWO
elevators which are powered by a piston that travels inside a cylinder.
Electric
Elevator
Hydraulic
Elevator
Traction
Elevator
Gearless
Elevator
The elevators require regular inspection and maintenance and generally have a life of _____ years.
5 years
10 years
15 years
20 years
are the moving step type lifts operating at constant speed between two levels in an inclined course for moving large number of people in a short time
Stairs
Elevator
Escalator
Conveyor
Most escalator are designed with ____ mm wide steps which allow passengers to move comfortably when carrying luggage and shopping bags
500 mm
1000 mm
1500 mm
2000 mm
Automatic centralized control of a building's HVAC and other
interrelated system.
High Tech
HVAC System
Intelligent
Building System
Building Automation
System
Smart
Automation System
a dynamic and responsive architecture that provides every occupant with productive, cost-effective and environmentally approved conditions through a continuous interaction among its basic elements; Places, Process, People, Management, Interrelation between them.
Smart
Buildings
Sustainable
Design
Intelligent
Buildings
Building Automation
System
_________ are the devices that monitor their environment and record or send that information (data) to a computer processor.
Sensor
Cloud
Camera
Hardisk
Designed to achieve the environmental requirements of the comfort
of occupants and a process.
Passive
Cooling
Active
Cooling
HVAC
Air
Conditioning
System
a compound typically found in either a fluid or gaseous state. It readily absorbs heat from the environment and can provide refrigeration or air conditioning when combined with other components such as compressors and evaporators.
Green Gases
Refrigerant
Condenser
Foam