Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical level one Module 8 section reviews

Total questions: 20

Worksheet time: 14mins

Name
Class
Date
1.

Information on conduit fill for various conductors can be found in NEC.

a)

Informative Annex A

b)

Informative Annex B

c)

Informative Annex C

d)

Informative Annex D

2.

If the conduit does not enter straight into the box,

a)

It may result in a voltage drop

b)

the fttings will be too tight

c)

A kick is required

d)

cut the conduit short

3.

Metal raceways and other enclosures are bonded to

a)

prevent leakage onto any electrical systems below

b)

Ensure electrical continuity and safely conduct any fault current

c)

ensure electrical continuity and safely conduct any leakage

d)

ensure mechanical continutiy

4.

Beam clamps are used with

a)

straps

b)

standoff supports

c)

framing channels

d)

Suspended hangers

5.

When installing conduit in a masonry environment, it is best to use

a)

3' to 5' lengths of conduit

b)

6' (1.8)lengths of conduit

c)

8' to 10' (2.4 m to 3 m) lengths of conduit

d)

20' (6m) lengths of conduit

6.

A fitting that does not require support

a)

outlet box

b)

pull box

c)

junction box

d)

conduit body

7.

The best tie wrap for outdoor use is

(a)  

8.

A type of fastener that uses the anchor itself as a drill bit is a

a)

wedge anchor

b)

stud anchor

c)

drive-type anchor

d)

Self-drilling anchor

9.

When installing hammer-driven pins and studs,

a)

the predrilled hole should be slightly smaller than the pin or stud

b)

the predrilled hole should be the same size as the pin or stud

c)

the predrilled hole should be slight larger than the pin or stud

d)

A predrilled hole is not required

10.

Which of the following is true regarding screw gauges and shank

a)

The lower the gauge number, the larger the diameter of the shank.

b)

The lower the gauge number, the longer the length of the shaft

c)

The higher the gauge number, the larger the diameter of the shange

d)

The higher the gauge number, the longer the length of the shank

11.

When using a powder-actuated tool

a)

post warning signs within 50' (15 m) of use

b)

power level 12 is the lowest

c)

color codes are often used to indicate the manufacturer

d)

All loads are interchangeable among makes an models

12.

A type of fastener that uses the anchor itself as a drill bit is a (a)   .

13.

Epoxy anchoring systems are commonly used to anchor fasteners in (a)   .

14.

Which of the following is true regarding wireways?

a)

Leave knockouts open in raintight troughs to allow for drainage

b)

Which of the following is true regarding wireways?

c)

Raintight lay-in wireways are the same as raintight troughs

d)

Troughs do not require knockouts because the conductors are fully enclosed

15.

Which of the following is true regarding surface metal raceways?

a)

They are typically used to carry service-entrance cable

b)

They can be used indoors and outdoors

c)

They are used in dry, interior locations only.

d)

They are typically installed on floors

16.

Special light-duty center-rail cable tray is most often used for (a)   .

17.

The type of cable tray support most likely to be used when power distribution and electrical wiring is routed over a large outdoor area is (a)   .

18.

When moving long pieces of raceway, it is best to (a)   .

19.

When storing raceway, it is best to (a)   .

20.

The maximum distance between wireway supports is

a)

5' (1.5m)

b)

10' (3m)

c)

15' (3m)

d)

20' (6m)