Minimum height of a handrail above the
stair thread.
.60 m
.70 m
.80 m
.90 m
Which is considered as a minor construction?
Minor structures 6sqm. or less detached from
other buildings, for private use only.
Open terraces or patios not exceeding 6sqm.
Open terraces or patios not exceeding 30sqm.
Minor structures 20sqm. or less detached from
other buildings, for private use only.
Which is considered as a minor construction?
Garden masonry walls not exceeding 1.0m in
height
Open terraces or patios not exceeding 6sqm.
Garden pools 500mm deep or shallower
Minor structures 20sqm. or less detached from
other buildings, for private use only.
Article 1723 of the Civil Code states that the
engineer or architect who drew up the plans and
specifications is liable for ___ years from
completion of the building should it collapse due
to defects in the plans or the ground.
15
10
5
3
Wood construction with fire-resistant material with one-hour fire-resistive throughout
TYPE 1
TYPE 2
TYPE 3
TYPE 4
▪Masonry and wood construction
▪ One hour fire resistive throughout
▪ Incombustible exterior walls
TYPE 1
TYPE 2
TYPE 3
TYPE 4
Type I construction NOT allowed
Non-fire restricted zones
Fire restrictive zones
Highly fire restrictive zones
Fire zones
BUILDINGS IN MULTIPLE FIRE ZONES Shall be considered as part of the more restrictive zone if more than ___of its total floor area is in
that zone
1/3
1/5
1/4
1/2
Land development or redevelopment schemes for
a new project which has a CDMP (Comprehensive
Development Masterplan) or equivalent
PUD
MIXED OCCUPANCIES
URBAN DESIGN
URBAN PLANNING
Reserved or leased parking slots may also serve
the parking requirements if the said parking building is not more than __ away, if residential
100m
200m
50m
60m
For traffic-generating buildings, the building ingress and the intersection shall be
at least __ apart (measured between the two
nearest curbs)
50m
100m
200m
60m
Interior or rear lots shall have an access road with
a minimum width of 3.00m. Provide a __ wide
chaflan at the intersection with the main RROW.
3.0 m
4.0 m
5.0 m
6.0 m
National roads or public highways: footings
located at least 2.40m below grade may project
__ (maximum) beyond the property line
300 mm
350 mm
200 mm
250 mm
Public sidewalk: Foundations may encroach
__ into the sidewalk if top of foundation is at
least 600mm below grade
450 mm
500 mm
200 mm
250 mm
No door or window shall project beyond the property
line when fully opened or upon opening unless at least __ above the pavement,
2.0 m
2.1 m
2.4 m
3.0 m
Double acting doors shall not be used as exits
when serving a tributary load of more than 100.
Must be provided with a view panel of not less
than __ sq. cm.
1300
1200
1400
1500
Occupant load: Classrooms
1.8sqm
0.65sqm
1.4sqm
2.8sqm
Occupant load: Conference Rooms
1.8sqm
0.65sqm
1.4sqm
2.8sqm
Minimum extended portion of a chimney
above the roof.
600mm
350mm
300mm
200mm
Minimum air space between walls of a
masonry chimney above the roof.
100mm
25mm
45mm
50mm
Minimum live load bearing capacity of a
construction canopy.
600 KGS / SQM
500 KGS / SQM
400 KGS / SQM
300 KGS / SQM
Minimum number of storeys requiring
one (1) or more dry standpipes.
2
3
4
5
Minimum firebox wall thickness
200
250
50
100
Minimum thickness of glass for
jalousies
5.6mm
5.5mm
5.4mm
5.8mm
Unit area per occupant for warehouses
and mechanical equipment room.
24sqm
25sqm
27sqm
28sqm