wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

ALE PD 1096

Total questions: 25

Worksheet time: 50mins

Name
Class
Date
1.

Minimum height of a handrail above the

stair thread.

a)

.60 m

b)

.70 m

c)

.80 m

d)

.90 m

2.

Which is considered as a minor construction?

a)

Minor structures 6sqm. or less detached from

other buildings, for private use only.

b)

Open terraces or patios not exceeding 6sqm.

c)

Open terraces or patios not exceeding 30sqm.

d)

Minor structures 20sqm. or less detached from

other buildings, for private use only.

3.

Which is considered as a minor construction?

a)

Garden masonry walls not exceeding 1.0m in

height

b)

Open terraces or patios not exceeding 6sqm.

c)

Garden pools 500mm deep or shallower

d)

Minor structures 20sqm. or less detached from

other buildings, for private use only.

4.

Article 1723 of the Civil Code states that the

engineer or architect who drew up the plans and

specifications is liable for ___ years from

completion of the building should it collapse due

to defects in the plans or the ground.

a)

15

b)

10

c)

5

d)

3

5.

Wood construction with fire-resistant material with one-hour fire-resistive throughout

a)

TYPE 1

b)

TYPE 2

c)

TYPE 3

d)

TYPE 4

6.

▪Masonry and wood construction

▪ One hour fire resistive throughout

▪ Incombustible exterior walls

a)

TYPE 1

b)

TYPE 2

c)

TYPE 3

d)

TYPE 4

7.

Type I construction NOT allowed

a)

Non-fire restricted zones

b)

Fire restrictive zones

c)

Highly fire restrictive zones

d)

Fire zones

8.

BUILDINGS IN MULTIPLE FIRE ZONES Shall be considered as part of the more restrictive zone if more than ___of its total floor area is in

that zone

a)

1/3

b)

1/5

c)

1/4

d)

1/2

9.

Land development or redevelopment schemes for

a new project which has a CDMP (Comprehensive

Development Masterplan) or equivalent

a)

PUD

b)

MIXED OCCUPANCIES

c)

URBAN DESIGN

d)

URBAN PLANNING

10.

Reserved or leased parking slots may also serve

the parking requirements if the said parking building is not more than __ away, if residential

a)

100m

b)

200m

c)

50m

d)

60m

11.

For traffic-generating buildings, the building ingress and the intersection shall be

at least __ apart (measured between the two

nearest curbs)

a)

50m

b)

100m

c)

200m

d)

60m

12.

Interior or rear lots shall have an access road with

a minimum width of 3.00m. Provide a __ wide

chaflan at the intersection with the main RROW.

a)

3.0 m

b)

4.0 m

c)

5.0 m

d)

6.0 m

13.

National roads or public highways: footings

located at least 2.40m below grade may project

__ (maximum) beyond the property line

a)

300 mm

b)

350 mm

c)

200 mm

d)

250 mm

14.

Public sidewalk: Foundations may encroach

__ into the sidewalk if top of foundation is at

least 600mm below grade

a)

450 mm

b)

500 mm

c)

200 mm

d)

250 mm

15.

No door or window shall project beyond the property

line when fully opened or upon opening unless at least __ above the pavement,

a)

2.0 m

b)

2.1 m

c)

2.4 m

d)

3.0 m

16.

Double acting doors shall not be used as exits

when serving a tributary load of more than 100.

Must be provided with a view panel of not less

than __ sq. cm.

a)

1300

b)

1200

c)

1400

d)

1500

17.

Occupant load: Classrooms

a)

1.8sqm

b)

0.65sqm

c)

1.4sqm

d)

2.8sqm

18.

Occupant load: Conference Rooms

a)

1.8sqm

b)

0.65sqm

c)

1.4sqm

d)

2.8sqm

19.

Minimum extended portion of a chimney

above the roof.

a)

600mm

b)

350mm

c)

300mm

d)

200mm

20.

Minimum air space between walls of a

masonry chimney above the roof.

a)

100mm

b)

25mm

c)

45mm

d)

50mm

21.

Minimum live load bearing capacity of a

construction canopy.

a)

600 KGS / SQM

b)

500 KGS / SQM

c)

400 KGS / SQM

d)

300 KGS / SQM

22.

Minimum number of storeys requiring

one (1) or more dry standpipes.

a)

2

b)

3

c)

4

d)

5

23.

Minimum firebox wall thickness

a)

200

b)

250

c)

50

d)

100

24.

Minimum thickness of glass for

jalousies

a)

5.6mm

b)

5.5mm

c)

5.4mm

d)

5.8mm

25.

Unit area per occupant for warehouses

and mechanical equipment room.

a)

24sqm

b)

25sqm

c)

27sqm

d)

28sqm