Fire Protection

Total questions: 43

Worksheet time: 43mins

Name
Class
Date
1.

Fire systems must operate off aircraft's?

a)

28VDC Hot battery bus

b)

28VDC Essential bus

c)

28VAC Essential bus

2.

Overheating systems are used in areas of?

a)

High temperature that may lead to fire

b)

Average temperature that may lead to fire

c)

Low temperature that may lead to fire

3.

What are thermostat switches or spot detectors know as?

a)

Thermal switch detector

b)

Thermocouples

c)

Continuous loop sensing elements

4.

What is the disadvantage of a thermal switch system operation?

a)

The test switch only test the system loop, not the individual sensors

b)

No redundant indication light

c)

The Bell Cancel light is fairly inconsistent in operation

5.

The individual switches can be tested in a thermal switch detector using?

a)

Ohmmeter

b)

Thermometer

c)

Frequency counter

6.

Installation of a switch with a different operating temperature in a thermal switch system will?

a)

Cause a false warning or no waring in event of fire

b)

Be compliant

c)

Cause complete system malfunction

7.

Which junction is open and is exposed to the air around it in a thermocouple fire detection system?

a)

Hot junction

b)

Cold junction

c)

Both

8.

When the hot junction in a thermocouple fire detection system is exposed to heat, there is an increase of current. The current is considered to be?

a)

Directly proportional to temperature

b)

Inversely proportional to temperature

c)

Linear proportional to temperature

9.

Thermal switches have to be tested with?

a)

Jet-Cal

b)

Thermostat

c)

Multi-meter

10.

What is used in a thermocouple fire detection system to detect a fire through an imbalance in temperature readings activating a warning?

a)

Reference thermocouple

b)

Thermal insulation

c)

Sensitive relay

11.

What type of testing is carried out on a thermocouple fire detector system?

a)

Continuity of the whole system

b)

Continuity of the system except the individual thermocouples

c)

Operation of the sensitive relay

12.

Which type of fire detection system permits more complete coverage of a fire hazard area than any other type of spot-type temperature detectors?

a)

Continuous loop

b)

Thermocouple

c)

Thermal switch

13.

Fenwal and Kiddle system are primarily used in fire detection and?

a)

Overheating detection in bleed air systems

b)

Overheating detection in engine exhaust systems

c)

Overheating detection in de-icing systems

14.

Which type of continuous loop fire wire system has a single conductor element construction consisting of a thin wall tube of approx. 2mm diameter made from Inconel filled with compound?

a)

Fenwal

b)

Kiddle

c)

Thermocouple

15.

What are the two types of Fenwal single conductor element fire wire?

a)

Ceramic beads and aluminium oxide in fibrous glass

b)

Nickle conductor with a thermistor and thermocouple

c)

Ceramic core and aluminium oxide

16.

When does the resistance increase in a ceramic bead type Fenwal conductor?

a)

When the salts cool

b)

When the salts heat up

c)

When temperature increases

17.

Which type of Fenwal conductor resistance of the compound lowers with heat and its dielectric qualities qualities improve so that the capacitance of the wire is higher as temperature increases?

a)

Ceramic beads

b)

Aluminium oxide

c)

Inconel

18.

What type of temperature coefficient is a Kiddle two conductor element wire?

a)

Negative

b)

Positive

c)

Neutral

19.

What principle does a pneumatic continuous loop system work on?

a)

Contained gas expanding due to heat

b)

Conductance through dissimilar metals

c)

Radiation or light between two surfaces

20.

Which fire detection unit senses an overall average temperature threshold and a localized discrete temperature increase cause by impinging flame?

a)

Pneumatic continuous loop

b)

Fenwal

c)

Kiddle

21.

How is discrete temperature sensing accomplished in a pneumatic continuous loop system?

a)

Hydrogen filled core material in a sensor tube

b)

Expansion of a fixed volume of helium gas inside the detector

c)

Stainless steel tube with an inert gas inside

22.

How is average temperature sensing activated in a pneumatic continuous loop system?

a)

Expansion of a fixed volume of helium gas inside the detector

b)

A hydrogen filled core material in the sensor tube

c)

A stainless steel tube with an inert gas inside

23.

Which function of a pneumatic continuous loop system is considered to be reversible?

a)

Average temperature

b)

Discrete temperature

c)

Both

24.

Which type of fire detection system is tested by a supply of low voltage AC current to the outer stainless steel casing?

a)

Lindberg

b)

Systron-Donner

c)

Thermocouple

25.

The test carried out on a Lindberg system verifies?

a)

Integrity of control unit, interconnecting of wiring and the detector unit

b)

The correct output from the AC bus and the functionality of the bell

c)

The functionality of the warning light, the interconnection of the wiring and the serviceability of the test unit

26.

If the integrity switch opens i.e the loop fails

a)

The system control box will isolate the defective loop and reconfigure to a single loop operation using the good loop system

b)

The system will completely fail and operation will seize

c)

The system control box will isolate the defective loop and reconfigure to a single loop operation using either loop system

27.

When replacing fire wire in a continuous loop fire detection system

a)

Ensure the wire is installed in the same path as the wire being replaced

b)

Ensure there is no bends sharper than a 2 inch radius

c)

The grommets are placed in a position so the wire can only touch the clamp if it moves

28.

If there is a single double break in the wire element, what will occur?

a)

Dead spot

b)

No change

c)

Short to ground

29.

What components in this system are able to be tested?

a)

Wiring

b)

Wiring and the switches

c)

Wiring and the relay

30.

What are the two main type of smoke detector systems?

a)

Photoelectric and ionisation

b)

Carbon monoxide and capacitance

c)

Reactive an proactive

31.

In a refraction smoke detection system, what angle is the photoelectric cell placed at relative to the light beam?

a)

90 degrees

b)

60 degrees

c)

30 degrees

32.

What is used in a refraction photoelectric system to form part of a test circuit which activates the photo diode to simulate a smoke condition?

a)

LED

b)

Beacon lamp

c)

Test lamp

33.

Which type of smoke detector has an electrode with a very small amount of radioactive material in one side of the smoke detection chamber?

a)

Ionisation type

b)

Comparison type

c)

Photoelectric type

34.

What can be used to provide a vacuum to draw air through he smoke detectors?

a)

Venturi ejector

b)

Fan

c)

Blower

35.

Turbine engine aircraft today are typically high rate of discharge system also know as?

a)

Fixed fire extinguishing

b)

Non-fixed fire extinguishing

c)

Floating fire extinguishing

36.

Which fire extinguishing system utilises halogenated hydrocarbons in one or more containers and a distribution system that releases the extinguishing agent through perforated tubing or discharge nozzles?

a)

HDR

b)

SDR

c)

Auxiliary

37.

What colour label are extinguishing agent pipelines and what shape is used?

a)

Brown and diamond

b)

Brown and triangle

c)

Brown and square

38.

What is the purpose of the RH engine fuel/fire sov?

a)

Turns fuel flow off to the engines

b)

Releases the two bottles for extinguishing

c)

Drives the solenoid to activate the selector switch

39.

What colour indicates high temperature on the indicator strip in a lavatory fire extinguishing system?

a)

Black

b)

White

c)

Red

40.

What is a negative to the fire extinguisher bottle in the lavatory fire extinguisher system?

a)

The bottle cannot be recharged

b)

It's operating temperature is only 60 degrees Celsius before it releases

c)

Difficult to access the storage area under each wash basin without damaging the furniture

41.

Where can an APU fire bottle be discharged from?

a)

Cockpit

b)

Remote location fire panel

c)

Both

42.

When checking APU extinguisher circuits, what must be used?

a)

Ohmmeter

b)

Safety ohmmeter

c)

Multimeter

43.

Where are water based or dry powder extinguishers not to be located?

a)

Pilot compartment

b)

Passenger compartments

c)

Under seats