High Voltage Tester requirements for SiC products

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

How big the voltage is under High-Voltage testing?

a)

DC voltage over 500V

b)

DC voltage over 1000V

c)

DC Voltage over 1500V

d)

DC Voltage over 2000V

2.

How big is the current that can kill human?

a)

less then 1mA

b)

less then 100mA

c)

less then 1A

d)

less then 5A

3.

What is typical Human Body resistance?

a)

50 Ohms

b)

250 Ohms

c)

500 Ohms

d)

5000 Ohms

4.

A company produces a SiC Mosfet and perform Breakdown voltage test at 2700 Volts. Can it kills human?

a)

yes

b)

No

c)

Yes if the human is thin.

d)

Yes if the human wear rubber shoes and very dry.

5.

My 1200 V SiC Mosfet will evolve to 4700 Breakdown voltage in the next 3 years. What kind of voltage ratings that should i buy for my tester?

a)

1500 V

b)

3000 V

c)

4500 V

d)

5000 V

6.

This fact is wrong.

a)

Cable must be designed to able to withstand to the max ratings of the tester

b)

Cable must be very short

c)

Cable must be designed to be able to dissipate heat

d)

Must have a thermometer in the fixture

7.

Raju designed two grounding paths with the same resistance value. He measured total cum contact resistance on the source to ground is 0.2 ohms. Raju run a HV testing that generates 100A of current, How much power is dissipated for each of the ground pin?

a)

500 Watt

b)

1000 Watt

c)

1500 Watt

d)

2000Watt

8.

Why HV test fixture must be properly grounded?

a)

to reduce the temperature at HV testing

b)

To ensure no sparking if overvoltage occured

c)

To ensure any leaking current to be absorbed by earth for safety to the operators

d)

to extend the reliability of the test fixture as they are normally very expensive

9.

Below are the reasons why we need to run HV testing as fast as possible except ...

a)

to minimize further loss due to power dissipation at the contacts resistance

b)

to minimize damage on fixture, device and other components if there is issue on contacts, wear and tear or human error.

c)

to reduce overheating in certain components for eg power cable

d)

It can cause power trip for the entire plant if run for too many testers

10.

What is Kelvin connection?

a)

is a connection that has sensor to measure the temperature

b)

it has a mechanism to convert oC to K. 1K = -273.15 oC

c)

it uses special material to reduce the overheating during HV testing

d)

It uses 4 terminal sensing to make more accurate measurements then the conventional 2 terminal type

11.

Which one is not true? based on the picture.

a)

The SOP must force operator to wear good quality of rubber shoes for safety purposes in HV testing

b)

Without good insulation on the operator, the High Voltage can cause severe injury and probability dealth to the operator

c)

Good grounding on the floor will save lives if electrical shock occured

d)

Food and drinks are not allowed in HV testing, because water is conductor and can promote grounding to the operators

12.

Why we need a counter at the HV test fixture?

a)

because the PM cud be scheduled accurately

b)

Counter will help to count how many units that passed the testing

c)

The counter will determine the life-span of the test fixtures.

d)

The counter will help in the UPH computation

13.

Below are the reasons why Batch ID for operators need to be scanned during HV testing except ....

a)

to store operators name in the DB

b)

The tester will automatically unlock for authorized operators

c)

for future references such as if there is an error found or any problems encountered due to human errors

d)

to unlock priveleges at all testers features based on user hierachy

14.

Rubber glove can protect from 12,000 V electric shock. Which one is false .....

a)

No, this statement is a myth.

b)

Yes provided the glove is thick enough for HV use

c)

Yes provided the gloves is 100% made from rubber

d)

Yes provided the gloves do not have any tear

15.

Select item which is not true about safety enclosure box in HV testing?

a)

It must be designed from good insulation materials to protect operators from electrical shock

b)

It must have temperature sensors

c)

The cable and materials must be design based on the max ratings of the testers

d)

Using with a safey interlock features at tester is an added advantages

16.

What is the best grounding resistance for equipments in plant?

a)

less then 100 Ohm

b)

less then 50 Ohm

c)

Less then 25 Ohm

d)

Less then 5 Ohm

17.

How ground fault circuit interruptor works?

a)

It compares current go and back from equipment

b)

It compares total current used by the loads

c)

It compared total Voltage used by the loads.

d)

It will trip if the current is more then trigger limit

18.

What is the safe distance from overhead lines?

a)

20 feet

b)

15 feet

c)

10 feet

d)

5 feet

19.

All of these statements are correct except ...

a)

Extension cords should not be used in office area

b)

extension cords should only be limited to maintenance personnel.

c)

employee should know the location of ELCB for their equipments

d)

Employee can plug out and plug in the power cord cable without looking at it.

20.

These are required in HV testing bay except ....

a)

HV gloves for the operator

b)

ESD suit

c)

Face protection apparatus

d)

linen thin smock shoes