WorksheetsAttendance Async W2
Total questions: 2
Worksheet time: 30mins
Name
Class
Date
1.
A 4 pole DC shunt generator generates 216 V when running at 600 rpm. The armature has 144 slots with 6 conductors each slot. Calculate Φ when its lap wounded.
Hint: More than 1 correct answer
a)
Number of poles = number of parallel path
b)
Number of conductors = 6
c)
flux per pole will be lesser when wound winding is applied
d)
Flux per pole = 25 mWb
2.
A 4 pole shunt generator with lap connected armature with armature and field resistance of 0.1 Ω and 50 Ω supplies 2400 W load at terminal voltage 100 V.
The values are true for
a)
Load current = 24 A
b)
Shunt current = 2 A
c)
Current per armature path = 6.5 A
d)
Armature voltage = 26 V
100 %