Based on Rule 8 of NBC, under Maximum Configuration of Basement Levels, what is the minimum RROW width that services the lot on which the basement can be constructed?
8m wide
10m wide
20m wide
24m wide
1. Based on Rule 8 of NBC, under Table 8.G.1 Easement Along Bodies/Way by Location, what is the minimum width of easement required for agricultural areas?
3m wide
10m wide
20m wide
40m wide
1. For a R-3 use or occupancy with a firewall on two (2) sides, a firewall can be erected on a maximum of of the total length of each side property line; provided that all firewall construction shall not exceed of the total perimeter of the R-3 property.
90%, 100%
85%, 50%
90%, 50%
85%, 65%
What is the maximum height to be allowed for buildings/structures based on their proposed use or occupancy?
Building Height Limitation
Building Height Limit
Building Height Restriction
Allowable Maximum Volume of Building
If only one (1) RROW services a lot and such is only 6.00 to 7.00 meters wide, what will be the maximum BHL number of shall be observed regardless of use or occupancy, lot size, lot dimensions, lot frontage and like considerations?
2 storey
2.5 storey
3 storey
9 storey
What is the Minimum Required Parking Slot for a MOTEL?
1 car slot for every unit
1 car slot for every 20 beds
1 car slot for every 5 rooms
1 car slot for every 2 units
Multi-floor parking garages may serve the 20% parking requirements of the building/structure within , provided at
least 80% of the parking requirements are complied with and integrated in
the building designs.
250m. radius
300mradius
200m radius
100m radius
Based on SECTION 708. Minimum Requirements for Group A Dwellings of Rule 7 NBC, Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least thick and below the surface of the ground.
250mm, 600mm
300mm, 600mm
200mm, 700mm
150mm, 650mm
1. Based on SECTION 708. Minimum Requirements for Group A Dwellings of Rule 7 NBC, All electrical installations shall conform to the requirements of the:
Philippine Electrical Engineer
Professional Electrical Engineer
Philippine Electrical Code
Philippine Electric Code
Based on SECTION 708. Minimum Requirements for Group A Dwellings of Rule 7 NBC, Mechanical systems and/or equipment installations shall be subject to the requirements of the:
Philippine Mechanical Engineer
Professional Mechanical Engineer
Philippine Mechanical Engineer Code
Philippine Mechanical Engineering Code
Base on National Building Code, OFB is defined as:
Outstanding Foundation of Building
Outermost Faces of Building
Outstanding Façade of Building
Outside Façade of Building
Formula in getting for the GFA of the building?
GFA = TGFA + non GFA
GFA = TLA x Multiplier
GFA = TLA x FLAR
All of the above
Which one is not considered part of the GFA?
Lobby
Office Space
Garden Deck
6sq. Balcony
Horizontal divisions of columbaria shall be of reinforced concrete of at least thickness.
100mm
25mm
75mm
50mm
Based on SECTION 803. Percentage of Site Occupancy of NBC, the measurement of the percentage (%) of site occupancy (or lot occupancy) shall be taken at what level?
Sidewalk Level
Ground Level
Road Level
Yard Level
Meaning of FLAR?
Floor Level Area Ratio
Floor to Lot Area Ratio
Floor and Lot Area Regulation
Floor to Lot Area Requirement
NBC Table for Minimum Setbacks for Residential Buildings/Structures?
Table 8.1
Table 7.1
Table 8.3
Table 8.2
What is the term for the required open space left between the outermost face of the building/structure and the property lines?
Setback
USA
Yard
Court
What is the term for the width of the yard?
TOSL
Dimension
Setback
Buffer
A front yard may be partly paved/hardscaped (converted into a courtyard) to serve as a carport but only for what zoning.
Basic R-2
Basic R-3
R-4 individual lot
all mentioned above
Based on SECTION 807. Air Space Requirements in Determining the Size of Rooms of NBC, how much number of person can possibly occupy an office with an area of 200sq.m. and 2.4m ceiling height?
200 person
120 person
40 person
80 person
Identify the illustration:
Rotunda
Turn Court
Cul-de-sac
Road Right of Way
It refers to the portion of the RROW reckoned from the natural grade line up to the finished surface of the roadway/carriageway and/ or the sidewalk/arcade.
RROW ABOVE GRADE
RROW AT GRADE
RROW BELOW GRADE
Road Right of Way
Eaves, canopies, awnings (or media agua) over required windows shall not be less than from the side and rear property lines.
500 mm
750 mm
1 meter
250 mm
The minimum width of the sidewalk for a RROW width of 9.00 meters or more shall be on each side of the RROW or a total of on both sides of the RROW.
900mm , 1.80m
750mm , 1.50m
1.20m , 2.40m
1.00m , 2.00m
Identify the illustration:
Inside Lot
Corner Through Lot
Interior Lot
Through Lot
Formula in getting AMVB:
AMBF x BHL (No. of Floors)
GFA x BHL meters
PSO x BHL meters
AMBF x BHL meters
Formula in getting TGFA:
TGFA = GFA + non GFA
TGFA = GFA x multiplier
TGFA = BHL x AMBF
All Mentioned Above
Based on SECTION 805. Ceiling Heights of NBC, habitable rooms provided with artificial ventilation shall have ceiling heights not less than
measured from the floor to the ceiling
2.70m
2.40m
2.10m
1.80m
The size of an average automobile (car) parking slot must be computed at for perpendicular or diagonal parking.
3m x 5m
2.50m x 6m
2.50 x 5m
2.10 x 5m