Worksheetscore quiz 2 August 22 - August 28
Total questions: 21
Worksheet time: 11mins
The ________program of the EPA identifies refrigerants with lower overall risks to human health and the environment.
WOW
ASHRAE
POE
SNAP
The difference between refrigerant grade hydrocarbon R-290 and propane for grills is the propane cylinders for grilling contains __________that can damage refrigeration equipment.
Carbon
Copper
Sulfer
impurities
Violations of the Clean Air Act can lead to fines up to
$25,000
$20,000
$44,539
$23,570
What should happen to an empty drum of refrigerant
refrigerant must be properly removed
any remaining refrigerant must be recovered
cylinder must be rendered useless & metal recycled
all of the above
________has the highest ODP value
CFC's
HCFC's
HFC's
Halons
EPA does not require tech's to keep records of model and serial numbers of appliances when disposing of appliance with ____________lbs of refrigerant.
200
150-200
100-300
5-50
Before disposing of any an appliance you must ___________ the refrigerant.
recycle
reclaim
recover
checked for acids
The refrigeration system is considered to be dehydrated when the vacuum indicator shows you have reached and held a vacuum of ____microns or less.
200
250
400
500
A recommended safety practice when operating refrigerant recovery or recycling equipment is to remain at least _________ft. away from any operating equipment.
50
40
25
5
The first publishings that ozone depletion could be a problem occured in the:
mid-70's
mid-80's
mid-90's
2000
The standard of Purity to ensure there is no contamination in refrigerants is
ARI 750
ARI 725
ARI 600
ARI 700
ODP is the measurement of a refrigerants ability to cause ozone decomposition in the stratosphere. R-______has been assigned an ODP value of 1.
R-11
R-12
R-134a
R-22
_____________refrigerants have the lowest GWP.
CFC
HCFC
HFC
HFO
One chlorine atom can cause the decomposition of approximately ____ozone molecules.
10,000
100,000
1000
100
Violations of the Clean Air Act could lead to
fines
loss of certification
requirement to appear in court
all of the above
Under the "safe disposal requirements", who is responsible for ensuring that the refrigerant has been removed from a refrigerator prior to disposal?
homeowner
service tech
person hauling off equipment
final person in the disposal chain
Carbon dioxide has a GWP of __________.
1
1430
3922
2088
The range displayed on a high pressure gauge on a service manifold is ______to_________psig.
0-800
0-250
0-500
0-425
What is the ODP value for R-134a
1.4
1.2
.57
zero
The Montreal Protocol agreement occured on:
July 1, 1992
September, 1987
December 31, 1989
September, 1990
If you Reclaim, you:
remove & store refrigerant from an appliance or other equipment
clean used refrigerant for immediate reuse
reprocess used refrigerant to new product specifications
none of the above
