NEW
Font size
WorksheetsEvaluation test
Total questions: 20
Worksheet time: 10mins
A BUNGALOW HOUSE IS CONSTRUCTED BETWEEN 2-STOREY HOUSES, WHAT IS THE SUGGESTED ROOFING MATERIALS TO BE USED?
ROOF TILES
ASPHALT SHINGLES
CORR. G.I. ROOFING
NONE OF THE ABOVE
ONE OF THE HISTORICAL STRUCTURE IN GREECE IS PATHENON, WHAT TRIANGLE IS WITHIN THE BUILDING FACADE WHICH APPLIED PRINCIPLE OF PROPORTIONING?
RIGHT TRIANGLE
ISOSELES TRIANGLE
SCALENETRIANGLE
EQUILATERAL TRIANGLE
IN A (45) FORTY-FIVE STOREY STRUCTURE WITH (5) FIVE BASEMENT LEVEL, THE TOP MOST FLOOR IS 45th FLOOR. WHAT IF A (45) LEVEL STRUCTURE WITH (5) FIVE BASEMENT LEVEL, WHAT WILL BE THE TOP MOST FLOOR?
40th FLOOR
45th FLOOR
41st FLOOR
50th FLOOR
IN A COLORWHEEL, CONSIDERING CONTRAST, YELLOW IS FOR VIOLET, RED IS FOR GREEN, WHAT ABOUT THE BLUE GREEN?
ORANGE
YELLOW ORANGE
RED ORANGE
BLUE VIOLET
COMMON PROBLEM IN SPRAYING LACQUER PAINT IS THE FOUL ODOR WHILE APPLYING IT, WHAT IS TO BE MIX ON THE PAINT TO ELIMINATE FOUL ODOR WHILE HAVING THE SPRAY APPLICATION?
ODOR NEUTRALIZER
LACQUER FLO
PERFUME
VANILLA
WHAT WATER SYSTEM TO BE USED ON A 2- STOREY RESIDENTIAL HOUSE KNOWING THAT THE WATER MAIN HAVE A NORMAL PRESSURE FROM 8PM TO 6AM AND THERE IS NO WATER AT ALL DURING 6AM TO 8PM?
UPFEED
PNEUMATIC
DOWNFEED
UPFEED/DOWNFEED
CONSIDERING THREE-PHASE POWER SUPPLY WITHIN THE STRUCTURE, HOW MANY WIRES WILL BE PROVIDED IN A UTILITY BOX FOR DUPLEX TYPE 2-POLE OUTLET?
2 WIRES
3 WIRES
4 WIRES
6 WIRES
BASED ON RULE VII & VIII, SECTION 808. WINDOW OPENING, WHAT SHOULD BE THE SIZE OF A SLIDING WINDOW, IF THE ROOM AREA IS 5.0M. X 6.0M.?
1.20M. X 2.0M
1.20M. X 1.50M
1.50M. X 2.0M
1.50M. X 4.0M
IN A RESIDENTIAL CONDOMINUM TOWER HAVING A MINIMUM CEILING HEIGHT WITHIN EVERY FLOOR, WHAT WILL BE THE MINIMUM AREA FOR A BEDROOM?
5.0 SQ.M.
6.0 SQ.M.
6.8 SQ.M.
7.8 SQ.M.
WHAT SERVICES PROVIDED IF THE ARCHITECT IS ALSO THE CONTRACTOR?
CONSTRUCTION SERVICES
PRE-DESIGN SERVICES
DESIGN BUILT SERVICES
NONE OF THE ABOVE
WHAT SERVICES PROVIDED IF THE ARCHITECT WILL ALSO WORK ON THE INTERIOR OF THE PROJECT?
INTERIOR DESIGNING
SPECIALIZED ALLIED SERVICES
CONSULTING ARCHITECT
SPECIALIZED ARCHITECTURAL SERVICES
WHICH OF THE FOLLOWING IS NOT A PRECAST?
PRE-TENSIONING
PRE CAST WALL
POST TENSIONING
LIFT SLAB
CLASSIFICATION OF WOOD USE FOR STRUCTURAL MEMBERS?
HARDWOOD
SOFTWOOD
DRYWOOD
ROUGH LUMBER
WHAT IS THE SIDE LAPPING OF CORR. G.I. ROOFING?
1
2
2 1/2
3
WHAT IS THE SIDE LAPPING OF CORR. G.I. ROOFING?
1
1 1/2
2
3
WHAT IS THE SIDE LAPPING OF CORR. G.I. ROOFING?
1 1/2
2
2 1/2
3
WHICH OF THE FOLLOWING MATERIALS IS USED FOR EXTERIOR CLADDING?
PEBBLES
GYPSUM BOARD
FABRIC
NONE OF THE ABOVE
WHAT IS THE MINIMUM SLOPE FOR CORRUGATED G.I. ROOF?
1
5
8
10
GIVEN A SIZE OF A TOILET AND BATH, 1.60M. X 2.40M., USING 20 X 30cm WALL TILES. QUANTIFY HOW MANY TILES IS NEEDED, IF THE HEIGHT OF THE WALL TILES IS 1.80M.?
222 pcs.
240 pcs.
264 pcs.
360 pcs.
GIVEN A ROOM SIZE OF 6.0M. X 6.0M., USING 6mm thk.- 4’ X 8’ GYPSUM BOARD AND 1/8” X 1” X 20’ ANGLE BARS, (HANGERS ARE NOT INCLUDED) @ 2’ ON CENTER, HOW MANY GYPSUM BOARD & ANGLE BARS IS NEEDED?
13pcs. of GYPSUM BOARD & 22pcs. of 1/8” X 1” X 20’ ANGLE BARS.
13pcs. of GYPSUM BOARD & 26pcs. of 1/8” X 1” X 20’ ANGLE BARS.
13pcs. of GYPSUM BOARD & 30pcs. of 1/8” X 1” X 20’ ANGLE BARS.
13pcs. of GYPSUM BOARD & 40pcs. of 1/8” X 1” X 20’ ANGLE BARS.
